Instructions

F G H I
N.C. COM N.O.
OUTPUT 2
DOOR
SENS GND
ALM
OUT
KEY
ACT
Connection terminal 2
Also be sure to note the example connection plans in these instructions when
connecting the device. These are located on the last page of these instructions.
A = TAMPER
This is the tamper switch output for the connection of an external alarm system.
H = High Potential, L = Low Potential, (N.C. contact)
B = Door bell connection (N.O. contact)
C = N.O. EG GND
Is for connection of an egress button
D = Operating voltage connection (12 V/DC)
E = OUTPUT 1
This is relay output 1, which has a variable contact (N.O. and N.C.).
F = OUTPUT 2
This is relay output 2, which has a variable contact (N.O. and N.C.).
G = “DOOR SENS” connection clamp
The “DOOR SENS” + “GND” allow you to connect a magnet contact or similar.
H = “ALM OUT” connection clamp
This is an alarm output for attaching, for example, an acoustic or optical signalling
device. This output delivers ground/earth potential as soon as it is activated.
I = “KEY ACT” connection clamp
Allows connection of an acoustic or optical signalling device. This output delivers
ground/earth potential as soon as it is activated.
39