Material Safety Data Sheet
5. Fire-fighting measures
Flash Point
N/A
Auto-Ignition Temperature
N/A
Extinguishing Media
Water, CO2.
Special Fire-Fighting Procedures
Self-contained breathing apparatus.
Unusual Fire and Explosion Hazards
Cell may vent when subjected to excessive heat-exposing battery contents.
Hazardous Combustion Products
Carbon monoxide, carbon dioxide, lithium oxide fumes.
6. Accidental release measures
Steps to be taken in case Material is Released or Spilled
If the battery material is released, remove personnel from area until fumes dissipate. Provide maximum ventilation to clear out
hazardous gases. Wipe it up with a cloth, and dispose of it in a plastic bag and put into a steel can. The preferred response is
to leave the area and allow the battery to cool and vapors to dissipate. Provide maximum ventilation. Avoid skin and eye
contact or inhalation of vapors. Remove spilled liquid with absorbent and incinerate.
Waste Disposal Method
It is recommended to discharge the battery to the end, to use up the metal lithium inside the battery, and to bury the
discharged battery in soil.
7. Handling and storage
The battery should not be opened, destroyed or incinerate, since they may leak or rupture and release to the environment the
ingredients that they contain in the hermetically sealed container. Do not short circuit terminals, or over charge the battery,
forced over-discharge, throw to fire. Do not crush or puncture the battery, or immerse in liquids.
Precautions to be taken in handling and storing
Avoid mechanical or electrical abuse. Storage preferably in cool, dry and ventilated area, which is subject to little temperature
change. Storage at high temperatures should be avoided. Do not place the battery near heating equipment, nor expose to
direct sunlight for long periods.
Other Precautions
The battery may explode or cause burns, if disassembled, crushed or exposed to fire or high temperatures. Do not short or
install with incorrect polarity.