Instructions
b) Remove the Junction Box Cover
• Insert a minus head screwdriver into a tab on the junction box cover and carefully pry it open.
If it does not release apply a twisting motion. Do not use force.
• Loosen the tip of the cable gland so the power cable can slide through.
c) Connect Power Supply Leads
Prepare Power Cable
• Remove the outer insulation on
the wires to a maximum length of
about 16 mm.
• Strip the insulation on each of
the wires on the mains cable to a
length of about 6 mm.
10 mm
6 mm
Connect Power Cable
• Feed the power cable through the cable gland.
• When the power supply leads reach the terminal block connectors, tighten the cable gland to
help prevent the cable from being pulled out.
IP65 Ingress protection warning. Check that the rubber gasket around the base
and tip of the cable gland forms a good seal around the power cable. This will stop
moisture from entering the cable inlet and damaging components inside the junction
box.
• When connecting power supply leads, match
colours as indicated. Brown (L), Blue (N).
Length of stripped wire must not be greater than
8 mm.
• Make sure that all screw connections on both
sides of the terminal block are sufficiently tight.
• Check that the wires are not squeezed, bent or
damaged in any other way.
N N
N
L L
L
d) Attach the Junction Box Cover
IP65 Ingress protection
warning. Make sure the
rubber gasket around the
junction is in place and
forms a good seal.
• Line the junction box cover tabs up
with the tabs around the junction box,
then “snap” shut.
• Check to make sure all the tabs are
“snapped” shut.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE. *1763873-5_v2_0319_02_dh_m_en
e) Attach Light Fixture to Mounting Brackets
• Line the light fixture mounting points up with
the mounting brackets and carefully press
together.
• The mounting brackets should “snap” into
place around the mounting points.
• Make sure the light fixture is securely
fastened to the mounting brackets before
letting go.
f) Switch the Electricity Supply ON
• Turn the corresponding circuit breaker and/or automatic
fuse back ON.
• If the lamp does not light up, turn OFF power to the
circuit immediately.
• Turn OFF the circuit breaker and/or automatic fuse.
• Check the connection to the power circuit.
ON
Connect Lamp Fixtures in Serial
Multiple light fixtures can be linked together and operated from a single switch.
Connecting the lamp fixtures in a serial wiring scheme must be carried out
by a qualified professional (i.e. an electrician) who is familiar with all applicable
regulations!
Care and Cleaning
• The LEDs are not replaceable. Turn off mains voltage to the light (or disconnect it from the
mains) and let it cool down sufficiently.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may
damage the casing or cause the product to malfunction.
• Use a dry, lint-free cloth to clean the product. To remove stubborn dirt, moisten the cloth
slightly with water.
• Never direct a garden hose or pressure washer etc. at the product.
• Do not wear metallic or conductive jewelry such as necklaces, bracelets or rings when
carrying out maintenance work on the product (including cleaning).
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines. You thus fulfill your statutory obligations and
contribute to the protection of the environment.
Technical Data
Input voltage / current ................... 220 - 240 V/AC, 50/60 Hz
Safety class .................................. Class 2
Colour temperature ....................... 4000 K
Material ......................................... ABS + PC cover
LED life ......................................... approx. 25000 hrs
LED beam angle ........................... 120°
Dimmable ..................................... No
Ingress protection rating ............... IP 65 (protection from low pressure water jets and dust)
Operating conditions ..................... -20 to +40 °C, 0 – 100 % relative humidity
Storage conditions ........................ -20 to +40 °C, 0 – 100 % relative humidity
Item No. 1763873 1763874 1763875
Max. number of fixtures
in serial connection
8 pcs 20 pcs 10 pcs
Max. lumens 3600 lm 1300 lm 2560 lm
LED lights 96 pcs 44 pcs 72pcs
Power consumption 45 W 16 W 32 W
Weight 1200 g 500 g 850 g