d) Programming watering times
Position WATER CYCLE: Set the cursor icon to “1” with the or buttons. Conrm
your selection with the OK or button to set the rst water cycle.
Position START TIME: Set the start time ( or button) and conrm (OK or button).
Position HOW LONG (watering duration): Adjust the watering duration ( or button) and
conrm (OK or button). Press and hold the or button for fast setting. The maximum
length is 240 minutes.
Set the duration for the watering cycles 2, 3, and 4 if needed.
e) Setting Eco mode
Position ECO FUNCTION (Eco mode): Enable the Eco mode if you wish to interrupt the
watering cycles. “WATER” ashes on the LC display. Set the time period for watering ( or
button) and conrm (OK or button). “PAUSE” ashes on the LC display. Set the time
period for the pause between water cycles ( or button) and conrm (OK or
button). The maximum time is 19 minutes.
Eco mode allows you to program individual watering times for various uses
(lawns, crop plants, etc.) and soil conditions. This helps for water absorption of
the soil, since the appropriate time setting allows the water level to drop
accordingly. After activating Eco mode, the setting is applied to all watering
cycles.
Example: Water cycle 1 = 60 minutes,
Irrigation for 6 minutes Pause for 3 minutes Irrigation for 6 minutes
Pause for 3 minutes ...
f) Programming irrigation type
Position PROGRAM (irrigation type): The available modes are Automatic, Rain delay, Manual
irrigation and Shut Down.
Set the cursor icon to AUTO ( or button) and conrm (OK or button) to start
automatic mode.
If it is supposed to rain soon, you can delay the program for up to 6 days. Set the cursor icon
to DELAY and conrm (OK or button). Use the or button to set the number of
days to delay the program. Conrm with the OK or buttons.
You can manually set the irrigation time during periods when no irrigation takes place. Set the
cursor icon to MANUAL and conrm (OK or button). Adjust the duration of watering.
See position HOW LONG. You may then activate Eco mode if desired. Set the cursor icon
to MANUAL again and conrm (OK or button). If no water is running or the device is
not connected to the water tap, the display shows the tap symbol . Open the tap.
If you wish to deactivate automatic irrigation for an extended period of time, set the cursor
icon to OFF ( or button) and conrm (OK or button). This suspends the set
irrigation program.
Maintenance and cleaning
Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could
damage the casing or cause the light to malfunction.
Use a slightly damp, lint-free cloth to clean the product exterior.
Disconnect the water timer from the water tap and hose at freezing temperatures and during
months when no irrigation is necessary.
Check the inside of the water tap connection (1) for contamination. Remove any dirt if present.
Dry the product prior to storing it. Store the product in a dry and frost-proof location out of
direct sunlight.
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in household
waste. Always dispose of the product according to the relevant statutory regulations.
Remove any inserted batteries and dispose of them separately from the product.
b) Batteries
You as the end user are required by law to return all used batteries. They must not
be placed in household waste.
Batteries that contain hazardous substances are labelled with this symbol to indicate
that disposal in domestic waste is forbidden. The abbreviations for heavy metals in
batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (shown on batteries, e.g.
below the trash icon on the left).
Used batteries can be returned to local collection points, our stores or battery retailers.
You thus full your statutory obligations and contribute to the protection of the environment.
Technical data
Battery operation .......................... 2 x 1.5 V battery, type AA
Water connection, inlet ................. 24.2 mm (3/4”)
Watering cycles ............................ up to 4 per day
Adjustable duration ....................... 1 to 240 min.
Eco mode ..................................... max. 19 min.
Water pressure ............................. 0 to 6 bar
Water temperature ........................ 0 to +60 ºC
Protection type .............................. IPX7
Operating/storage conditions ........ 0 to +60 ºC, 10 % - 95 % RH
Dimensions (W x H x D) ............... 130 x 170 x 95 mm
Weight .......................................... approx. 315 g