Product Manual

© 2005, Glentronics, Inc. 1806018
BATTERY
Possible Reasons
The battery fluid is low . . . . . . . . . . . . . . . . . . . . . . . . . . .
BATTERY
Possible Reasons
Terminals are corroded . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cables are loose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery is discharged below 25% . . . . . . . . . . . . . . . . . . . .
Battery is damaged or old . . . . . . . . . . . . . . . . . . . . . . . . .
POWER
Possible Reasons
Power outage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
An outlet, fuse or circuit breaker has failed . . . . . . . . . . . . .
The power cord is unplugged from the wall . . . . . . . . . . . . .
The charger is receiving less than 110 volts from the outlet . .
PUMP
Possible Reasons
Backup pump is unplugged . . . . . . . . . . . . . . . . . . . . . . . .
Backup pump is broken . . . . . . . . . . . . . . . . . . . . . . . . . . .
Backup pump is clogged . . . . . . . . . . . . . . . . . . . . . . . . . .
PUMP WAS
Possible Reasons
The main AC pump failed because of a power outage . . . . . . .
The main AC pump is broken . . . . . . . . . . . . . . . . . . . . . . .
The float switch on the main pump is jammed or defective . .
The main AC pump could not keep up with the inflow of water .
The check valve is stuck or installed improperly and the water
returns to the sump pit . . . . . . . . . . . . . . . . . . . . . . . . . . .
The discharge pipe is blocked and the water returns to the
sump pit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BATTERY FUSE
Possible Reasons
Pump is clogged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump wires are exposed . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump is broken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BATTERY HOOKED
Possible Reasons
The unit will not operate . . . . . . . . . . . . . . . . . . . . . . . . . .
FLUID LOW
Remedies
Add distilled water to the battery
PROBLEM
Remedies
Clean terminals & cables
Tighten wing nuts
Replace battery if power is out. There is only 1 hour of continuous
pumping power left. Battery will recharge when power is restored
Replace battery
FAILURE
Remedies
None. The backup pump will run on the battery
Try another outlet, replace the fuse or reset the circuit breaker
Make sure the power cord is plugged in securely
None, if the utility company has instigated brown outs. Otherwise, reduce
the number of other appliances on the circuit
FAILURE
Remedies
Make sure the pump is securely plugged into the back of the control unit
Replace the pump
Remove strainer and clean out any debris
ACTIVATED
Remedies
None. The backup pump was activated
Replace the main AC pump
Free the float switch or replace it
None. The backup pump was activated. If this is a recurring problem,
install a higher capacity main pump
Replace the check valve or correct the installation
Clean out or replace the discharge pipe
HAS BLOWN
Remedies
Remove pump and strainer. Clean out any debris. Replace the 25-amp DC
fuse
Replace the pump
Replace the pump
UP BACKWARDS
Remedies
Reverse the battery connections
Troubleshooting Guide
Read safety warnings & instructions before attempting any repairs or maintenance.
!
DANGER
Page 15