Operating Guide
6
© 2020. All rights reserved.
4. Remove any dirt or accumulated debris from the
sump pit and surrounding area. Clean out the
vent hole in the discharge pipe.
NOTE: If the sump basin is larger than 18-in.
diameter, the DC pump can be installed with the
primary pump on the same level or slightly higher
than the primary pump. If the sump basin is smaller
than 18-in. diameter, the DC pump will be installed
above the primary sump pump.
5. Disconnect or cut the main discharge pipe and
separate the primary sump pump from the
discharge pipe. Remove the pump from the
sump basin.
115 V
GFCI outlet
5
DC pump
installed
above primary
pump
Less than 18”
Clean
vent hole
Remove
debris
4
INSTALLATION INSTRUCTIONS