User Manual

WaterTecS100UserManual 8
Step2Mount&WiretheS100
MountingtheS100
MounttheS100nearyoursprinklermer.WhiletheS100iswaterresistantandis
appropriateforwallmountedexteriorinstallaons,theunitisnotwaterproof.Donot
mounttheS100inabelowgradelocaon.
WiringtheS100totheSprinklerTimer
1.Onthesprinklermer,disconnectthewirethatisconnectedtothecommon
terminal,andthenconnectthatwiretotheWHITEwireintheS100bundle.
2.ConnecttheBLACKwireintheS100bundletothecommonterminalonthe
sprinklermer.
3.Onthesprinklermer,ndtheterminalforthevalvewherethebiSensoris
connected.Disconnectthewirefromthatvalveterminal,andthenconnectitto
theREDwireintheS100bundle.
4.ConnecttheGREENwireintheS100bundletotheterminalonthesprinklermer
thatthevalvewirewasconnectedto.
5.ConnecttheORANGEwiretothe24voltsAC(VAC)terminalonthesprinkler
mer.Ifyoursprinklermerhasmorethanone24VACterminal,touchthe
orangewiretooneoftheterminalstondtheone thatsuppliespower.TheS100
displaywillturnonwhenitreceivespower.
6.Oponal:ConnecttheBLUEorBROWNwiretotheterminal
ofavalvethatyou
donotwantunderS100control.Thebypassedvalvewilloperatesolelybasedon
theconguraoninthesprinklermerwithoutanyinputfromtheS100. Donot
disconnectthevalvewiresfromtheterminalsofthevalvesthatarebypassed.
IMPORTANT!
Theonlyvalvewirethatyoudisconnectfrom
thesprinklermeristheoneforthevalve
wherethebiSensorisconnected.Leaveall
othervalvewiresconnectedtothemer.