User Manual

BaselineInc. 19
Er5isdisplayed
(PressRead/Setto
clearthiswarning
message.)
Unexpectedreading
during24hourauto
calibraonnalreading
wasnotsubstanally
dierentfromtherst.
 Makesurenoextrawateris
appliedtothebiSensoraer
autocalibraonstartsorthe
S100maysetaunacceptable
threshold.
Er6isdisplayed Unexpectedlowreading
duringthe24hourauto
calibraon.
 Ensuresoiliscompactedaround
sensorwithnotairpocketsor
rockstouching.
 Resaturatesoil,andthenrerun
the24–hourautocalibraon.
Displayisblank
LEDsareoff
S100isnotreceiving24
VAC.
 Makesurethe24VAC
transformerispluggedinand
receivingpower
 Ensurethe24VACwireand
commonwirefromtheS100are
properlyconnected.
biSensorisreading
avalueunder20
Soilappearswet
Theremaybeairpockets
aroundthebiSensor.
 ReburythebiSensor.
 BeespeciallycarefulthatNO
rocksaretouchingthebladeof
thesensorasthiscanleadto
falsereadings.
Controllerdoes
nothaveaccessto
24VAC
Someoldermechanical
controllersdonothave
accessto24VAC.
 Purchaseandinstalla24VAC
transformer.
 Formoreinformaon,contact
Baselinesupportat
8662945847.
ErrorCodeor
Condition
Status RecommendedAction