User Manual
BaselineInc. 17
Er1 CommunicaonError
IncorrectWiring
BadConnecons
DamagedWire
Er2 OverCurrentError
BadValveSolenoid
ShortCircuitWires
Er3 BadReadingfrombiSensor
biSensorsckisdamaged
biSensorisnotburiedinthe
ground
Er4
24‐hourAutoCalibraon
Failed
Thiserroralsodisplaysoneof
theothererrorcodeslistedin
thistabletoindicatethe
reasonforthefailure
Er5
ValueOutofRangeError
duringthe24‐hourAuto
Calibraon
ThisindicatesthebiSensor
readingsfalloutsideofthe
expectedrange.
Canbecausedbyfailureto
saturatethesoilinthe
beginningorbythewatering
ofthesiteduringcalibraon.
IfanER4occurred,theS100
willwaterbasedonthe
previouslysetthreshold.
Er6
LowReadingduringthe24‐
hourAutoCalibraon
Thisindicatesthattherewas
alowreadingduring
calibraon.Re‐runtheauto
calibraon.
Removeanyairpockets
aroundsensor.
ErrorCode Status Cause
ErrorCodes
AnerrorcodeontheS100warnsthatanirregularcondionhasoccurred.Eventhough
yourirrigaonsystemwillconnuetowaterwhenanerrorcodedisplaysontheS100,
youshouldrefertotheErrorCodetablebelowandtheTroubleshoongseconon
pages18
‐19todeterminethestatusoftheS100andtakeaconasnecessary.
Toclearanerrorcode,brieflypresstheRead/Setbuon.