User Manual

BaselineInc. 15
Step6CalibratetheSensor(AutoCalibrationMode)
TheS100hasanAutoCalibraonmodethatrunsfor24hours.Autocalibraonsets
themoisturethresholdbasedonyoursoiltype.Thisisimportantfornewinstallaons
andusefulforrecalibrangabiSensor.
1.HeavilysaturatethesoilaroundthebiSensorwithwater.Ifthe
soilisnotproperly
saturated,theautocalibraonwillfail.
2.Aerthewaterhassoakedintothesoil,brieypresstheRead/Setbuononthe
S100totakethecurrentmoisturereading.Writedownthecurrentdate,me,
andmoisturereadingtobeusedas
areferencepoint.
Date:_______________Time:__________MoistureReading:___________
2.Pressandholdthe+,,andBypassbuonssimultaneouslyfor3seconds.The
displaywillashbetweenCAL,24H,andthemoisturereading.Thedisplaywill
countdown,onthehour,unlthecalibraoniscomplete.
Wateringisstopped
whiletheS100isinAutoCalibraonmode.DonotallowthebiSensortoreceive
anywaterduringcalibraon.Thisprocesswillfailorprovidefalsefeedbackifit
does.
NotesontheAutoCalibrationProcess

ToexittheAutoCalibraonmode,pressandholdtheRead/Setbuonfor3
seconds.
 Ifthecalibraonsucceeds,themoisturethresholdwillbeautomacallyset,and
thesystemwillallowwateringwhensoilmoisturedropsbelowthisthreshold.
 Ifanerroroccursduringautocalibraon,thescreenwillashEr4indicangthat
calibraonfailed.TheEr4codeisfollowedbyanothercodewithanumberthat
correspondstothereasonforfailure.SeetheTroubleshoongseconfor
informaononthevariouserror
messages.
 Iftheautocalibraonfails,theS100willwaterbasedonthepreviouslyset
threshold.
 IfthebiSensorreceiveswaterduringthe24hourcalibraonperiod,orthesoil
wasnottotallysaturated,thecalibraonwilleitherfailenrelyorsetanincorrect
thresholdforyourlawn.Ifthishappens,youwillneedtoresaturatethesoiland
restarttheautocalibra
on.
 Ifthethresholdsetbytheautocalibraonisunacceptable,trythemanual
calibraonprocessdescribedonthenextpage.