User Manual
BaselineInc. 13
biSensorBurialRequirements
EnsurethereisgoodcontactbetweenthesoilandthebiSensor.
BurythebiSensorsoitisresngonitslongedge.IfthebiSensoris
buriedflat,thereadingscanbewrongduetomoisturepoolingonthe
surfaceofthebiSensor.
BurythebiSensor2”to3”deepinturfareasanddeeperforplanters
andtreeareas(rootzones).
Re-cover area and
heavily saturate withwater.
Cut slit into grass
about 12” long
by 6” deep...
then work shovel
back andforth to
create a slot for the biSensor
Bur y biSensor
4” TO 6” deep
Bur y biSensor
2”TO 3” deep
OptionBworkswellinsandyorloamysoils.
1. Withaflatbladeshovel,cutaslitinthegrasswhere
thebiSensorwillbeplaced.Widentheslitwitha
backandforthmoon.
2. PlacethebiSensorintheslithorizontallysothetop
ofthebiSensoris2”‐3”deep.
3. Removeanyrocks
orgravelthataretouchingthe
biSensortoensuretherearenoairpockets.
4. Cutaslitbacktothevalveboxforthe
communicaonwires.Takecaretoburythemdeep
enoughtoavoiddamagefromaeraonorother
acvies.
5. Usingabucketof
water,saturatethesoil
surroundingthebiSensorandcompactthesoil
arounditghtly.
Step4–BurytheBiSensor(OptionB)