User Manual

BaselineInc. 13
biSensorBurialRequirements

EnsurethereisgoodcontactbetweenthesoilandthebiSensor.
 BurythebiSensorsoitisresngonitslongedge.IfthebiSensoris
buriedat,thereadingscanbewrongduetomoisturepoolingonthe
surfaceofthebiSensor.
 BurythebiSensor2”to3”deepinturfareasanddeeperforplanters
andtreeareas(rootzones).
Re-cover area and
heavily saturate withwater.
Cut slit into grass
about 12 long
by 6 deep...
then work shovel
back andforth to
create a slot for the biSensor
Bur y biSensor
4 TO 6” deep
Bur y biSensor
2TO 3 deep
OptionBworkswellinsandyorloamysoils.
1.Withaatbladeshovel,cutaslitinthegrasswhere
thebiSensorwillbeplaced.Widentheslitwitha
backandforthmoon.
2.PlacethebiSensorintheslithorizontallysothetop
ofthebiSensoris2”3”deep.
3.Removeanyrocks
orgravelthataretouchingthe
biSensortoensuretherearenoairpockets.
4.Cutaslitbacktothevalveboxforthe
communicaonwires.Takecaretoburythemdeep
enoughtoavoiddamagefromaeraonorother
acvies.
5.Usingabucketof
water,saturatethesoil
surroundingthebiSensorandcompactthesoil
arounditghtly.
Step4BurytheBiSensor(OptionB)