Owner's manual

FGR2-PE Wirelss Data Transceiver
LUM0024AB Rev A
Options: Any whole, negative number between -100 and -70 db, in increments of 5.
Description: If the Noise Alarm Enable option is set to Enabled, a trap condition occurs if
the Noise Level goes above the value in this parameter.
Noise Alarm Enable
Web Parameter: Noise Enable check box in the SNMPTrap Limits section of the SNMP page.
Network Type: Both
Default Setting: Disabled
Options: Disabled, Enabled
Description: Enables a trap for the Noise Level of the transceiver. The trap condition is
present based on the settings in the Noise Alarm Above parameter.
Rx Rate Alarm Below
Web Parameter: Rx % Rate Below in the SNMPTrap Limits section of the SNMP page.
Network Type: Both
Default Setting: 50
Options: Any percentage between 50 and 100, in increments of 5.
Description: If the Rx Rate Alarm Enabled option is set to Enabled, a trap condition
occurs if the receive percent goes below the value in this parameter.
Rx Rate Alarm Enable
Web Parameter: Rx % Rate Enable check box in the SNMPTrap Limits section of the SNMP
page.
Network Type: Both
Default Setting: Disabled
Options: Disabled, Enabled
Description: Enables a trap for the receive percentage of the transceiver. The trap condition
is present based on the settings in the Rx Rate Alarm Below parameter.
Signal Alarm Below
Web Parameter: Signal Alarm Below in the SNMPTrap Limits section of the SNMP page.
Network Type: Both
Default Setting: -90
Options: Any whole, negative number between -100 and -70 db, in increments of 5.
Description: If the Signal Alarm Enable option is set to Enabled, a trap condition occurs
if the signallevel goes below the value in this parameter.
82