Owner's manual

FGR2-PE Wirelss Data Transceiver
LUM0024AB Rev A
Object Description Access Syntax
fwtPlusModemRxSubnetID A numerical ID that radios use to decide
which subnet they are allowed to link to.
Read/Write Unsigned32 (
0..15 )
fwtPlusModemTxSubnetID A numerical ID that radios use to decide
which subnet they will transmit on.
Read/Write Unsigned32 (
0..15 )
fwtPlusModemReboot Set to 1 to reboot radio. This will force any
changes to take effect.
Read/Write INTEGER (
0..1 )
fwtPlusModemMaxSlaveRetry The maximum number of times an
Endpoint can attempt to deliver data to the
Gateway before it discards the data.
Read/Write Unsigned32 (
0..9 )
fwtPlusModemSystemName A textual identifier for a given system. Read/Write DisplayString
( SIZE ( 0..32
) )
fwtPlusModemFreqZoneIndex An index used to identify a specific
frequency zone for a specific radio
modem.
Not
Accessible
Unsigned32
fwtPlusModemFreqZoneDescr A textual description of a specific
frequency zone for a specific radio
modem.
Read Only DisplayString
fwtPlusModemFreqZoneEnabled If the value of this object is true(1) then the
referenced frequency zone is enabled for
the relevant radio modem; if the value of
this object is false(2), then the frequency
zone is disabled.
Read/Write TruthValue
Group Object Description Objects
fwtPlusModemSupplyVoltageBad This notification is generated
when the supply voltage for a
radio modem goes out of
specification.
fwtPlusModemSupplyVoltage
fwtPlusModemVendorString
fwtPlusModemSystemName
fwtPlusModemRxRateBad This notification is generated
when the receive rate for a
radio modem goes out of
specification.
fwtPlusModemRxRate
fwtPlusModemVendorString
fwtPlusModemSystemName
fwtPlusModemTxRateBad This notification is generated
when the transmit rate for a
radio modem goes out of
specification.
fwtPlusModemTxRate
fwtPlusModemVendorString
fwtPlusModemSystemName
130