AirWerx 90 Installation & Operations Manual Patented Tel: 1-888-641-8862 Web: www.baseaire.com E-mail: sales@baseaire.com Specifications subject to change without notice.
Table of Contents Warranty Registration ......................................2 Safety Notes ...................................................2 Identification ...................................................3 Electrical Supply..............................................3 Principle of Operation.......................................3 Installation ......................................................3 Key Functions .................................................5 Indicator Lights ...................
Warranty Registration Congratulations on purchasing a new AirWerx 90 Dehumidifier. Your new dehumidifier comes with an extensive warranty plan. To register, simply fill in and return the warranty card provided in your dehumidifier box. Be sure to note your dehumidifier serial number as you will need it for registration. Safety Notes The AirWerx Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances ).
Identification For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific unit.
Step #1: Place dehumidifier on a level surface. If the unit is handled in such a manner that the compressor did not remain in the upright position, you will need to place it on a level surface and wait a minimum of 2 hours before turning the unit "on". NOTE: Do not place directly on vapor barrier. Elevation is required to allow the condensate water to drain via gravity. Step #2: Set Up Drain Line The drain line should be routed to a suitable drain on the outside.
Key Functions 1. Power Key · Use this button to turn the dehumidifier on and off. Press once to turn the machine on. You will hear two beeps and the light will illuminate green. Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a one minute fan delay on shutdown. 2. Arrow Buttons · Use the up and down arrow buttons to set the desired humidity setpoint on the display screen.
Indicator Lights 1. Humidity Display Screen ·The display screen has two functions: 1. When the unit is powered on, it shows the humidity of the space. 2. While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to the current humidity level. 2. Power Indicator Light ·This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is "off" prior to performing any service. 3.
1. On/Off( Power) Button Press the on/off button and the machine will start running (two beeps). Press the button again to the turn the machine off. 2. Up Button /Down Button Use the Up and Down arrow buttons to adjust the humidity level. 3. Mode M Use the mode button to switch between dehumidification and a ducted application. The symbol on the display board indicates the sensor on the remote control is being utilized.
Airwerx 90 Diagram Power cord Handle Unit Cover Air Intlet Grille Inlet End Cap Drain Hose Front View Power cord Unit Cover Remote control Control panel Air Outlet Grille Discharge End Cap Back View Maintenance WARNING: Always unplug the unit before doing any maintenance. Cleaning the machine body Use a soft damp cloth to clean the exterior of unit. Do not use any soap or solvents. Cleaning the filter 1. Unplug the unit. 2. Slide out the filter. 3.
Electrical Access ·Unscrew the 4 screws on the side panel to access the control board. Dehumidifier Storage If the unit will be stored for an extended period of time, complete the following steps: 1. Turn off the unit and allow to dry. 2. Wrap and secure the power cord. 3. Cover the filter mesh. 4. Store in a clean, dry space. Ducted Applications Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room.
Flex Duct Installation Rotate the flex duct counter-clockwise. Flex Duct Removal Rotate flex duct clockwise or remove wire tie. Troubleshooting Symptom Machine Won’t Run Cause Solution Power Supply Verify that there is power to the outlet and that the plug is properly installed in outlet. Room Temperature Over 105℉ (Display HI) or Below 33℉ (Display LO) The unit id outside the operating temperature range.
AirWerx 90 Spare Parts All AirWerx Models-Parts Part# Description A-100 Remote Control Package (cable+remote) A-101 A-103 Remote Control Remote Control Cable, 26’ Return Duct Collar Accessory A-106 Duct Kit Assembly ( W-103+ W-100) A-107 Flexible Supply Duct, 72" A-108 A-109 Main Control Board Display Board A-110 RH/Temperature Sensor A-102 AirWerx 90-Parts Part# Description A-902 Fan Motor Complete Fan Assembly Fan Capacitor A-903 Compressor A-9
Limited Warranty All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned. 1 YEAR ( FROM DATE OF PURCHASE): BaseAire warrants the dehumidifier will operate free of defects in workmanship and materials.
Limited Warranty Exclusions EXCLUSIONS: DAMAGE DUE TO THE FOLLOWING IS NOT COVERED UNDER WARRANTY 1. ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO: ● FLOODING ● FIRE ● WATER DAMAGE ● HURRICANE STORM DAMAGE 2. IMPROPER USAGE-INCLUDING BUT NOT LIMITED TO: ● POOL/SPA/TUB APPLICATIONS ● MISUSE, ABUSE OR TAMPERING WHETHER INTENTIONAL OR ACCIDENTAL ● IMPROPER INSTALLATION OR DESIGN ● MPROPER VOLTAGE ● LACK OF NORMAL CARE ● FAILURE TO FOLLOW INSTRUCTIONS 3. CORROSION 4. FREEZING 5.