AirWerx 55 Installation & Operations Manual Patented Tel: 1-888-641-8862 Web: www.baseaire.com E-mail: sales@baseaire.com Specifications subject to change without notice.
Table of Contents Warranty Registration ......................................2 Safety Notes ...................................................2 Identification ...................................................3 Electrical Supply..............................................3 Principle of Operation.......................................3 Installation ......................................................3 Key Functions .................................................5 Indicator Lights ...................
Warranty Registration Congratulations on purchasing a new AirWerx Dehumidifier. Your new dehumidifier comes with an extensive warranty plan. To register, simply fill out and return the warranty form provided in the dehumidifier box. Be sure to note your dehumidifier serial number as you will need it for registration. Safety Notes The AirWerx Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances).
Identification For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific machine.
Step #1: Place dehumidifier on a level surface. Do not place directly on vapor barrier. For example, use blocks, or pavers to create a level surface. If the unit is handled in such a manner that the compressor did not remain in the upright position, it is necessary to place on a level surface and wait a minimum of 2 hours before turning the unit "on". NOTE: AirWerx 55 Dehumidifiers can't sit directly on the floor unless the unit is feeding directly into a sump pump next to it.
Key Functions 1. Power Key · Use this button to turn the dehumidifier on and off. Press once to turn the machine on. You will hear two beeps and the light will illuminate green. Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a one minute fan delay on shutdown. 2. Arrow Buttons · Use the up and down arrow buttons to set the desired humidity setpoint on the display screen.
Indicator Lights 1. Humidity Display Screen ·The display screen has two functions: 1. When the unit is powered on, it shows the humidity of the space. 2. While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to the current humidity level. 2. Power Indicator Light ·This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is "off" prior to performing any service. 3.
1. On/Off( Power) Button Press the on/off button and the machine will start running (one beep). Press the button again to the turn the machine off. 2. Up Button /Down Button Use the Up and Down arrow buttons to adjust the humidity level. 3. Mode M Use the Mode button to switch between dehumidification and a ducted application. The symbol on the display board indicates the sensor on the remote control is being utilized.
AirWerx 55 Diagram Power cord Handle Remote control Unit Cover Control panel Drain Connect Front View Power cord Handle Unit Cover MERV 8 Filter Outlet End Cap Humidity Sensor Maintenance Back View WARNING: Always unplug the unit before doing any maintenance. Cleaning the machine body Use a soft damp cloth to clean the exterior of unit. Do not use any soap or solvents. Cleaning the filter 1. Unplug the unit. 2. Slide out the filter. 3.
Dehumidifier Storage If the unit will be stored for an extended period of time, complete the following steps: 1. Turn off the unit and allow to dry. 2. Wrap and secure the power cord. 3. Cover the filter mesh. 4. Store in a clean, dry space. Ducted Applications Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room. The supply grille is designed for 6" flex ducting. Be sure to secure the ducting with tie wrap.
Troubleshooting Symptom Machine Won’t Run Cause Solution Power Supply Verify that there is power to the outlet and that the plug is properly installed in outlet. Room Temperature Over 105℉ (Display HI) or Below 33℉ (Display LO) The unit id outside the operating temperature range. Modify the room conditions so the temperature is between 33°-105℉ and operation will commence. Air Filter is Clogged Clean the filter mesh according to instructions listed in manual. Air Inlet or Outlet is Blocked.
AirWerx 55 Spare Parts All AirWerx Models-Parts Part# Description A-100 A-101 A-102 A-107 A-108 A-109 A-110 Remote Control Package (cable+remote) Remote Control Remote Control Cable, 26’ Flexible Supply Duct, 72” Main Control Board Display Board RH/Temperature Sensor AirWerx 55-Parts Part# Description A-500 A-501 A-502 A-503 A-504 A-505 A-506 A-508 A-509 A-510 A-513 Fan Motor Complete Fan Assembly Fan Capacitor Compressor Compressor Capacitor Coil Assembly Hot
Limited Warranty All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned. 1 YEAR ( FROM DATE OF PURCHASE): BaseAire warrants the dehumidifier will operate free of defects in workmanship and materials.
Limited Warranty Exclusions EXCLUSIONS: DAMAGE DUE TO THE FOLLOWING IS NOT COVERED UNDER WARRANTY 1. ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO: ● FLOODING ● FIRE ● WATER DAMAGE ● HURRICANE STORM DAMAGE 2. IMPROPER USAGE-INCLUDING BUT NOT LIMITED TO: ● POOL/SPA/TUB APPLICATIONS ● MISUSE, ABUSE OR TAMPERING WHETHER INTENTIONAL OR ACCIDENTAL ● IMPROPER INSTALLATION OR DESIGN ● MPROPER VOLTAGE ● LACK OF NORMAL CARE ● FAILURE TO FOLLOW INSTRUCTIONS 3. CORROSION 4. FREEZING 5.
Scan QR Code to Register Warranty