Installation Guide

WALL
JAMB
NYLON
SPACER
#8 x 2” TRUSS
HEAD SCREW
Replace one wall jamb [B] and attach to the
wall with a #8 x 2” truss head screw [D] inserted
through the center hole. Slip a nylon spacer [E] over a
#8 x 2” truss head screw and install in the top hole
of the wall jamb. Repeat for the bottom jamb. Check
jamb for plumb and tighten screws.
NOTE: Do not over-tighten the jamb screws.
4
This bath enclosure is equipped with safety tee
lock wall jambs. When installed properly, the header is
permanently locked to the wall jambs and cannot be
accidentally dislodged.
Measure the wall-to-wall opening at the top of the wall
jambs [B] and cut the header [F] 1/16” short of this
dimension. Check the header for fit.
Slide the safety tee-lock of the unmounted wall jamb
into the header.
Holding the header at an angle, engage the end onto the
mounted wal
l jamb. Pivot the header into place, then
slide the loose wall jamb to
the wall and press into
position on the tub track. Attach to the wall per
instructions in Step #4.
5
6
HEADER
WALL
JAMB
#8 x 2” TRUSS
HEAD SCREW
QCI5022 REV.3
If not already, slide the anti-jump inserts to the center of the header.
NOTE: Header shown
and cut away for clarity
Certified 10/12/17
HEADER
ANTI-JUMP