Installation Guide
HINGE LEFT HINGE RIGHT
 ALSO
CORRECT
MEASURE
SHOWER 
 SILL
CURB
WEEP HOLE
INTERIOR
CURB
CURB
INTERIOR
WEEP HOLE
WALL
JAMB
WALL
JAMB
WALL
1 The Shower Enclosure is completely reversible 
and may be installed hinge right or hinge left. For 
maximum leak protection, the hinge side should be 
opposite the shower head. Using the illustration, 
determine the proper hinge side for the door. This 
instruction sheet depicts a hinge-right installation. 
Careful as to not follow the illustrations exactly.
CAUTION: For safety reasons, the door must 
always open outward.
TIP: Temporarily cover the drain on the inside 
of the shower with some tape or a large peice of 
cardboard to prevent small screws, drill bits, etc 
from disappearing.
2  Measure the finished wall-to-wall opening 
at the shower sill. Cut the curb (w/ weep holes) [A] 
to fit the full width of the opening. If necessary, file 
the ends or corners of the curb to tightly fit the opening.
Place the curb in the center of the sill with the weep 
holes facing the shower. Mark itβs location on the sill, 
both inside and outside, with a pencil the full length 
of the curb.
TIP: Use two pieces of tape over the top of the curb 
to temporarily hold it in place.
3  Place one wall jamb [D] into the curb against the 
wall. Using a level, plumb the wall jamb and mark the 
hole locations on the wall with a pencil. Repeat this step 
for the other wall jamb. Remove all parts and drill the holes.
Tile or marble walls:
Drill 3/16β diameter holes into the walls and insert the 
plastic wall anchors [B]. 
Fiberglass or acrylic units can be done two different ways: 
If the walls are not reinforced, drill 3/16β diameter holes 
and insert the the plastic wall anchors. (Toggle bolts may 
be used instead but they are not provided).
If the walls are reinforced, only drill 1/8β diameter holes.
QCI5230 Rev 0 Page 4 Certified 06/20/2016