Table 5 – Gas data
Description
PM8…. .
PM9…. .
PM9DG200 PM1.G200 PM1.G300 PM1.G500
Lower
calorific
value
H
i
Rated heating power
kW
21 32 34.5 48 65
Minimum power kW
7 15 22.5 26.5 33
Gas connection R”
½” ½” ½” ½” ½”
G20 –
2H
m
3
/h
2,22 3,38 3,65 5,07 6,88
kWh/m
3
9,45
Consumption
G30 – 3+ Kg/h
1,65 2,52 2,72 3,78 5,13
kWh/kg
12,68
Pilot
40 40 40 40 40
Maximum
3 X 205 4 X 225 4 X 225 4 X 280 4 X 310
G20
20 mbar
Minimum
ADJUST
.
ADJUST. ADJUST. ADJUST. ADJUST.
Pilot
20 25 25 25 25
Maximum
3 X 135 4 X 145 4 X 150 4 X 185 4 X 195
Nozzles diameter in 1/100
mm
G30
28-30/37
mbar
Minimum
ADJUST
.
ADJUST. ADJUST. ADJUST. ADJUST.
G20
23 10 30
Primary air
distance
G30
mm
30
OPEN
30
OPEN OPEN
Description
PM9.G170GN PM9.G270GN PM9.G370GN Lower calorific value
H
i
Rated heating power
kW
30 44 49
Minimum power kW
17,8 20 24
Gas connection R”
½” ½” ½”
G20 –
2H
m
3
/h
3,17 4,65 5,18
kWh/m
3
9,45
Consumption
G30 –
3+
Kg/h
2,36 3,47 3,86
kWh/kg 12,68
Pilot
40 40 40
Maximu
m
6 X 175 10 X 170 14 x 150
G20
20
mbar
Minimum
ADJUST. ADJUST. ADJUST.
Pilot
25 25 25
Maximu
m
6 X 115 10 X 110 14 x 80
Nozzles diameter in 1/100
mm
G30
28-
30/37
mbar
Minimum
ADJUST. ADJUST. ADJUST.