Table 2 – Sizes
(see figure “Size of appliance and position of connections”)
Specifications Models
Description Unit of
measure
ment
PM8… PM9… PM9DG200 PM1.G200 PM1.G300 PM1.G500
Width (A) mm
800 900 900 1000 1150 1150
Depth (B) mm
900 900 1150 1300 1300
Height (C) mm
900 950 900 900 1050
Vat diameter mm
600 600 750 900 900
Specifications Models
Description Unit of
measurement
PM9.G170GN PM9.G270GN PM9.G370GN
Width (A) mm
1000 1400 1800
Depth (B) mm
900 900 900
Height (C) mm
900 900 900
Vat diameter mm
700X550 1100X550 1500X550
Table 3 – General water data
Specifications Models
Description
Unit of
measurement
PM8…. . PM9…. .
PM9DG200
PM1.G200 / 300 / 500
PM9…GN
Cold water connection mm
10 ½”
Hot water connection mm
10 ½”
Water pressure kPa
50 – 300
Table 4 – Minimum output setting
PM8… ./PM9…. . PM1.G200 PM1.G300 PM1.G500
G 20 – 20 mbar 2,5 mbar 8,6 mbar 5,6 mbar 5 mbar
G 30 – 28-30/37 mbar 3 mbar 12 mbar 8,5 mbar 7,25 mbar
PM9.G170GN PM9.G270GN PM9.G370GN
G 20 – 20 mbar 7,5 mbar 4 mbar 3,5 mbar
G 30 – 28-30/37 mbar 11,6 mbar 5,5 mbar 10,5 mbar