3.6. HOW TO PROCEED, IF …
Warning! : Problems and failures may occur even when the appliance is used properly. Here is a
list of the mist probably situations and controls that the operator should perform to
avoid applying to a service centre unnecessarily.
If the problem is not solved after the necessary controls, turn off the appliance immediately,
cut off any supplies and apply to a service centre.
… the vat contents do not heat
up:
− check that there is gas in the mains and that the cock is open;
− check that the main burners are on.
− Otherwise turn off the unit and apply to a service centre, as the
safety thermostat may have been activated because of an excess
of temperature in the cooking vat. This occurs aspecially wehn the
appliance is started and the vat and/or jacket is/are empty or when
the appliance needs servicing because the burners are dirty and
clogged.
4.1. SIZE OF APPLIANCE AND POSITION OF CONNECTIONS
Models PM8.G… / PM9.G… .
LEGEND:
T - Technical data plate
A - Hot water connection 10 mm
G - Gas connection R ½” in conformity with ISO 7-1 B - Cold water connection 10 mm
S - Overflow