ELECTRIC KETTLES INDIRECT
“PM8-9IE..A” “PM1IE..A” “PMRIE..A” “PM9IE..GN”
3 USE AND CLEANING
3.1 WARNINGS AND HINTS FOR USER
This manual contains all the instructions required for a proper and safe use of our appliances.
Keep the manual in a safe place for future consultation!
This appliance is for catering use, hence they must be used only by trained kitchen staff.
The appliance must always be kept under control during use.
Warning! : The manufacturer shall not be held responsible for injuries or damage due to the non-
compliance with safety rules or an improper use of the appliance by the operator.
Some improper operating conditions may even be caused by an improper use of the appliance, therefore it
is important to train personnel properly.
All the installation and maintenance operations must be performed by fitters who are members of
an official register.
Respect the periods required for maintenance. With this is mind, customers are recommended to sign a
service agreement.
In case of failures concerning the appliance, all outputs (electrical power supply and water) must be cut off
instantly.
In case of recurrent failures, contact a service technician.
3.2 INSTRUCTIONS FOR USE
Before cooking with the appliance for the first time, wash the interior of the cooking vat
thoroughly.
Warning! : Fill the cooking vat up to a maximum of 40 mm under the overflow border, according to
the maximum level mark, including the food to be cooked.
Warning! : Before filling the vat, always check that the drainage tap is closed.
3.2.1 FILLING THE JACKET
MOD. 100-150 lt
Warning! : The water level in the jacket must be checked each time before lighting.
Warning! : It is advisable to use softened water to fill the jacket!
Open the level tap on the front of the appliance.
Unscrew the filling cap on the safety valve unit. The latter is on the right of the appliance surface (see
figure “Size of appliance and position of connections ”).
Fill with softened water (the capacity of the jacket is stated in the paragraph “Technical data”).
When water flows out of the level tap, close it and screw back on the safety unit cap.
Mod. PM1IE200/300/500 – PMRIE100/150/200/300/500/510 – PM9IE170/270/370GN
Warning! : The water level in the jacket must be checked each time before lighting.
Warning! : It is advisable to use softened water to fill the jacket!
Open the level tap on the front of the appliance.