Operation Manual

EN
page 43
7. SIGNALS AND ALARMS
The alarm messages are displayed, based upon their meaning.
When displaying "PRESS WATER SOFTNER REGENERATION KEY" a total regeneration
is needed (only with optional water softener).
When displaying "DETERGENT LEVEL" add detergent in the detergent tank (only with
optional "Sensor for Chemicals Low Level").
When displaying "RINSE-AID LEVEL" add rinse-aid chemical in the rinse-aid tank (only
with optional "Sensor for Chemicals Low Level").
When displaying "SALT LEVEL" add salt in the container in the wash-tank (only with optional
water softener).
When displaying "SHUT DOOR" means that the open door does not allow the maneuver
tried, or a wash cycle was in progress, when lifting the door.
When displaying "DRAIN WATER IN WASH TANK" means that a full wash-tank does not
allow the maneuver tried.
When displaying "SELF-CLEANING: REMOVE FILTERS AND PRESS START" the machine
requires a self cleaning cycle.
When displaying "SELF-CLEANING CYCLE OVER" the machine ended the self-cleaning
cycle.
Table 3
TYPE OF ALARM CAUSE REMEDIES
B1 BOILER FILLING FAIL
Open the water supply valve and verify a proper water
supplyow.ContactTechnicalService
B2 BOILER PROBE FAIL.
Contact Technical Service
B3 BOILER HEAT. ALARM
Contact Technical Service
B4 RINSING FAILED
TIME OUT RINSE
Contact Technical Service
B5 BOILER OVERHEATING
Contact Technical Service
E1 WATER LOAD FAILED
Open the water supply valve.
Contact Technical Service
E2 TANK PROBE FAIL.
Contact Technical Service
E3 TANK HEATING ALARM
Contact Technical Service
E5 TANK OVERHEATING
Contact Technical Service
E6 TANK DRAINING FAIL.
Checktheoverowpipe.ContactTechnicalService
Z4 TANK SENSOR FAILURE
Contact Technical Service
Z5 TANK HIGH LEVEL Drain and load the tank.
Contact Technical Service
Z6 TANK LOW LEVEL Drain and load the tank.
Contact Technical Service
Z9 REGENERATION FAIL