Use and Care Manual
REMOTE OPERATION
7
Remote Control Operation:
Power Button: Press this button to start unit when it is energized or stop the unit when it is in operation.
Timer Button: Press this button to set unit automatic on and off time.
High Button: Press this button to select high speed of fan running (except dry
and sleep modes).
Low Button: Press this button to select low speed of fan running.
Up Button: Press this button to increase temperature or timer setting.
Down Button: Press this button to decrease temperature or timer setting.
°C °F Button: Press this button to make Celsius degrees and Fahrenheit
degrees interchange.
Cool Button: Press this button to select “COOL” mode.
Fan Button: Press this button to select “FAN” mode.
Dry Button: Press this button to select “Dry” or “dehumidifying” mode.
Sleep Button: Press this button to select “SLEEP” function under cooling mode.
Before using your remote, install the AAA batteries into remote control.
1. Press and glide the battery cover on the back of the remote control, then you
can remove the cover.
2. Insert two new alkaline AAA batteries into the battery compartment. Be sure to
note the proper polarity.
3. Reattach the battery cover and make sure the locking tab clicks into place.
Use alkaline batteries only. Do not use rechargeable batteries.
When replace batteries, always replace both batteries with new batteries, do not mix old and new batteries.
If the air conditioner will not be used for an extended period of time, remove the batteries from the remote
control.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water, do not
use the remote control if the batteries have any leakage. If you eat the liquid from the batteries,
brush your teeth and see doctor. The chemicals in batteries could cause burns or other health
hazards.
Multiple Protection Functions:
1. Anti-freeze protection function Compressor, water spraying motor will turn off when compressors running
over 10 minutes and tube temperature (Tp) is continuously <35.6°F(2°C) for 20 seconds under cooling mode,
E4 will show on LED display window, the unit initiates the anti-frost protection and all buttons on control panel
(except for power button) are inactive.
2. Water-full safety alarm and shut –off protection function: Warning sounds when the water volume reached
its alarm level in water tank, and unit is automatically stop working, both water-full indicator and “FL” on LED
window is ashing. You need to drain the condensate for unit to automatically recover operation. (For more
information about how to drain, refer to the “Drainage Instruction”).
3. Delay protection function of compressor This unit offers restart protection to compressor. Except that the
compressor may start immediately when the unit is energized at rst time, there is 3-minute start delay after
compressor is shut down.