Mounting instructions Class D/E, CAT 6 Outlet
1. Preparation of the cable ends
Remove cable sheathing approx. 50 mm in length. Cut back overall screen to
approximate 15 mm, remove twisted pair screen as required. To ensure contact of
the screen the diameter of the cable end must be 6 to 10 mm. If cable is too thin fold
back screen over cable cover. To improve contact wind self-adhesive screening foil
over the screen (approx. 2 turns, optional), bend tracing wire over that.
2. Mounting of the cables with one twin cable clip
Both cables are mounted in the top cover with a
bolt through the cable clamp; this ensures screen
contact.
Strain relief with cable tie on top cover is possible
(not included in delivered state).
3. Recommendation – Colour code
TIA/EIA-568-B
Colour Terminal
WH-OG
OG
1
2
WH-GN
GN
3
6
WH-BU
BU
5
4
WH-BN
BN
7
8