User manual
User manual POLARIS Remote 19.1" / Remote 15"
16
Page 16
3. Terminal assignment
3.1 Overview of connections
3.2 Terminal assignment EEx i
Terminal Interface Colour Signal Remarks
Scanner connection
(optional)
X1 Hand-held scanner +UB Supply voltage +5 V
X2 Hand-held scanner RxD-I Data input RS232 signal
X3 Hand-held scanner GND Mass connected to protective earth
PS/2 interface for input devices
X4 PS2 WH/BR VCC Supply voltage
X5 PS2 GN/YE GND Mass connected to protective earth
X6 PS2 PK KB_CLK Keyboard clock signal
X7 PS2 GR KB_DATA Keyboard data signal
X8 PS2 BL MS_CLK Mouse clock signal
X9 PS2 RD MS_DATA Mouse data signal
Sealed screw plug.
Do not open!
Ex i Terminal chambe
r
Terminal X1-X9
USB plug for USB Stick
Ex e Terminal chamber
Terminal X10-X20
Label of tpye
ST plug for connection to local unit
(only at POLARIS Remote with fibre optic)