Betriebsanleitung/Operation instructions UL
Decode zone for MC 9060
ex
-G (Lorax Extended Range Scan Engine)
18
Example of connection MC 9060
ex
-G
Safe area
Access Point
Server
Access Point
ex
Ethernet
MC 9060
ex
-G
MC 9060
ex
-G
MC 9060
ex
-G
Width of field
Distance from front of scan engine
Note: Typical performance at 73.4 °F (23 °C)
on high quality symbols
inch 0 120 240 360 480 600
cm 0 304.8 609.6 914.4 1219.2 1524.0
55 mil
70 mil reflective
100 mil reflective
180.015.0
367.0
542.0
SE 1524
inch cm
72 182.9
48 121.9
24 61.0
00
24 61.0
48 121.9
72 182.9