USER INSTRUCTIONS IDMxxx corded Hand-held Scanners
General Remarks User Instructions IDM corded General Remarks Further information on the IDM corded Hand-held scanners can be found on the internet on the IDM product page at www.mysick.
User Instructions Table of contents IDM corded Table of contents 1 2 Getting Started..................................................................................................................................................... 5 1.1 Getting familiar with your IDM Hand-held scanner......................................................................... 5 1.2 Connectivity ..............................................................................................................................
Table of contents User Instructions IDM corded 3 4 2.5.3 Delay Settings .................................................................................................................... 46 2.5.4 Emulation Settings, Key Pad Emulation, Upper/Lower Case Settings ........................... 47 2.6 Serial Interface Control................................................................................................................... 48 2.6.1 Record Suffix, Preamble, Postamble Settings ................
Getting familiar with your IDM Hand-held scanner User Instructions IDM corded 1 Getting Started 1.1 Getting familiar with your IDM Hand-held scanner The IDM family includes 1D scanners with linear imagers and 2D scanners with area imagers. There are different models available. IDMx20 and IDMx40 can be used for general purpose applications whereas IDMx60 is designed for industrial environments.
Connectivity User Instructions IDM corded To connect the scanner, plug the cable into the interface port of the scanner and connect it to the host. To remove the cable, straighten one end of a paper clip and insert it into the cable release hole to pull out the cable. For IDM160/260 series you need to push down the bracket of the enclosure clip and pull out the cable. IDM120 Series IDM140/240 Series IDM160/260 Series Depending on the Scanner model different cables have to be used.
Technical Specifications User Instructions IDM corded 1.3 Technical Specifications Type IDM120 IDM140 IDM160 IDM240 IDM260 Field of application General Purpose General Purpose Industrial General Purpose Industrial Enclosure rating IP 41 IP 41 IP 65 IP 41 IP 65 Supported code types 1D, Stacked 1 1D, Stacked, 2D ≥0.102 mm1) ≥0.076 mm1) SR model: ≥0.08 mm1), ≥0.18 mm2) HD model: ≥0.08 mm1), ≥0.13 mm2) 50 mm ... 600 mm (0.5 mm)1) SR model: 30 mm ... 155 mm (0.
Programming Commands User Instructions IDM corded 2 Configuration 2.1 Programming Commands The IDM scanner bar code commands are specially designed proprietary bar code labels which allow you to set the IDM Scanner’s internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Each programmable family and bar code command label is listed on the same page with major system commands.
Programming Procedures User Instructions IDM corded If the programming family must take “Multiple Scan Selection”, “Cycling Scan Selection”, or “Dual Level Selection” procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) listed in the following table. Conventions Descriptions Factory default value Programming category SS: Single scan selection P.C.
Programming Procedures User Instructions IDM corded 2.2.2 System List & Master Default Scan „M_DEFAULT” Scan „SYSLIST“ The scanner will list the product information and revision number to host via selected host interface, then issue the completion beeping. The scanner will list the product information and revision number to host via selected host interface, then issue the completion beeping. 2.2.3 Single Scan Selection Scan „PROGRAM“ Yes Enter Programming mode.
Programming Procedures User Instructions IDM corded 2.2.4 Multiple Scan Selection Scan „PROGRAM“ Yes Enter Programming mode. Scan one of family codes Select the desired programming family. Scan one or several option codes Select one or several option codes for the desired parameters. If it‘s necessary scan „FIN“ to terminate the option code selection. Repeat selection Do you want to select another programming family? No Scan „END“ 8015906/2013-07-02 Exit programming mode.
Programming Procedures User Instructions IDM corded 2.2.5 Cycling Scan Selection Scan „PROGRAM“ Yes Enter Programming mode. Scan one of family codes Select the desired programming family. Scan one or several option codes Select one or several option codes for the desired parameters as “Single” or “Multiple” scan selection. Scan “FIN” Finish cycling selection. (If necessary) Repeat selection Do you want to select another programming family? No Scan „END“ 12 Exit programming mode.
Programming Procedures User Instructions IDM corded 2.2.6 Dual Level Scan Selection Scan „PROGRAM“ Scan one of family codes st (1 ) Scan several option codes nd (2 ) Scan one or several option codes Yes Repeat selection Enter Programming mode. Select the desired programming family. Select several option codes for the desired parameters. 1. Select one or several option codes for the desired parameters. 2. If it’s necessary scan “FIN” to terminate the option code selection.
Host Interface Selection User Instructions IDM corded 2.3 Host Interface Selection PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4 Symbology Reading Control 2.4.1 User Defined Symbol ID PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.3 Readable Bar Code Setting If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, adding the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology. PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded PROGRAM Family Code Selection F_DEFAULT P.C. Parameter Selection Option Code Readable Symbology CS QR Code */ Micro QR Code * A0 Setting CS Data Matrix * A1 CS Aztec Code * A3 CS Australian Post B0 CS British Post B1 CS Intelligent Mail barcode B3 CS Japanese Post B4 CS KIX Post B5 CS Planet Code B6 CS Postnet B8 Above symbologies marked with * are enabled as default.
Symbology Reading Control User Instructions IDM corded 2.4.4 Code 39/ Code 32 Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.5 Code 39 Settings PROGRAM F_DEFAULT Family Code Selection P.C. Parameter Selection Option Code Code 39 Security Level SS Level 0 0 SS Level 1 1 SS Level 2 2 SS Level 3 3 Code 39 Security Level The scanner offers four levels of decode security for Code 39 bar codes: Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1 please select level 0.
Symbology Reading Control User Instructions IDM corded 2.4.6 Codabar/ NW-7 Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.7 UPC-A/ UPC-E Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes. Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may increase the misread.
Symbology Reading Control User Instructions IDM corded 2.4.8 EAN Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded Supplement Scan Voting The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3.
Symbology Reading Control User Instructions IDM corded UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner.
Symbology Reading Control User Instructions IDM corded 2.4.10 IATA & Interleaved 2 of 5 Settings PROGRAM 28 F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.11 Code 25 Family Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.12 Code 11 & Code 93 Settings PROGRAM F_DEFAULT Family Code Selection P.C. Code 11 Settings SS Disable Code 11 0 SS Enable Code 11 1 SS Disable check digit verification 2 SS Select 1-check digit verification 3 SS Select 2-check digit verification 4 SS Disable check digit transmission 5 SS Enable check digit transmission 6 SS Default (04) MS 01-Maximum Code 11 Min.
Symbology Reading Control User Instructions IDM corded 2.4.13 MSI/ Plessey Settings PROGRAM F_DEFAULT Family Code Selection P.C. MSI/ Plessey Settings SS Disable MSI/Plessey 0 SS Enable MSI/Plessey 1 SS Select MOD 10 check digit 2 SS Select MOD 10-10 check digit 3 SS Select MOD 11-10 check digit 4 SS Disable check digit transmission 5 SS Enable check digit transmission 6 SS Default (04) MS 01-Maximum MSI/ Plessey Min.
Symbology Reading Control User Instructions IDM corded 2.4.14 Code 128 Settings PROGRAM F_DEFAULT Family Code Selection P.C. Code 128 Settings SS Disable Code 128 0 SS Enable Code 128 1 SS ISBT Concatenation Off 2 SS ISBT Concatenation On 3 SS Default (01) MS 01-Maximum Code 128 Min. Length Parameter Selection Option Code FIN (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. Code 128 Max.
Symbology Reading Control User Instructions IDM corded 2.4.15 GS1-128 Settings PROGRAM F_DEFAULT Family Code Selection P.C. GS1-128 Settings SS Disable GS1-128 0 SS Enable GS1-128 1 SS Default (01) MS 01-Maximum GS1-128 Min. Length Parameter Selection Option Code FIN (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. GS1-128 Max.
Symbology Reading Control User Instructions IDM corded 2.4.16 UK/ Plessey Settings PROGRAM F_DEFAULT Family Code Selection P.C. UK/ Plessey Settings SS Disable UK/Plessey 0 SS Enable UK/Plessey 1 SS Select UK/Plessey Standard Format 2 SS Select UK/Plessey CLSI Format 3 SS Disable Convert X to A-F 4 SS Enable Convert X to A-F 5 SS Disable check digit transmission 6 SS Enable check digit transmission 7 SS Default (04) MS 01-Maximum UK/ Plessey Min.
Symbology Reading Control User Instructions IDM corded 2.4.17 Telepen Settings PROGRAM F_DEFAULT Family Code Selection P.C. Telepen Settings SS Disable Telepen 0 SS Enable Telepen 1 SS Select Telepen Numeric mode 2 SS Select Telepen Full ASCII mode 3 SS Disable check digit transmission 4 SS Enable check digit transmission 5 SS Default (04) MS 01-Maximum Telepen Min.
Symbology Reading Control User Instructions IDM corded 2.4.18 GS1 DataBar Settings PROGRAM F_DEFAULT Family Code Selection P.C. GS1 DataBar Settings SS Disable GS1 DataBar (RSS-14) 0 SS Enable GS1 DataBar (RSS-14) 1 SS Disable GS1 DataBar Limited 2 SS Enable GS1 DataBar Limited 3 SS Disable GS1 DataBar Expanded 4 SS Enable GS1 DataBar Expanded 5 SS Default (04) MS 01-Maximum GS1 DataBar Min.
Symbology Reading Control User Instructions IDM corded 2.4.19 Composite Codes, Codablock F, PDF417, Micro PDF417 Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.20 Code 16K & Code 49 Settings PROGRAM F_DEFAULT Family Code Selection P.C. Code 16K Settings SS Disable Code 16K 0 SS Enable Code 16K 1 SS Default (01) FIN MS 01-Maximum Code 16K Min. Length Parameter Selection Option Code (3 digits) Scan 3 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. Code 16K Max.
Symbology Reading Control User Instructions IDM corded 2.4.21 QR Code Settings PROGRAM F_DEFAULT Family Code Selection P.C. QR Code Settings SS Disable QR Code 0 SS Enable QR Code 1 SS Disable MicroQR Code 2 SS Enable MicroQR Code 3 SS Disable QR Code Append 4 SS Enable QR Code Append 5 SS Disable QR Code Inverse Reading 6 SS Enable QR Code Inverse Reading 7 SS Auto detect QR Code Inverse Reading 8 SS Default (01) MS 01-Maximum QR Code Min.
Symbology Reading Control User Instructions IDM corded 2.4.22 Data Matrix Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.23 Aztec Code Settings PROGRAM F_DEFAULT Family Code Selection P.C. Aztec Code Settings SS Disable Aztec Code 0 SS Enable Aztec Code 1 SS Default (01) MS 01-Maximum Aztec Code Min. Length Parameter Selection Option Code FIN (4 digits) Scan 4 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. Aztec Code Max.
Symbology Reading Control User Instructions IDM corded 2.4.24 Autralian Post, US Planet, US Postnet, British Post, Japan Post Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Symbology Reading Control User Instructions IDM corded 2.4.25 Netherland KIX Code, Intelligent Mail & Korea Post Code Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Keyboard Interface Control User Instructions IDM corded 2.5 Keyboard Interface Control 2.5.1 Keyboard Layout (Language) Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Keyboard Interface Control User Instructions IDM corded 2.5.2 Record Suffix, Preamble, Postamble, FNC1 Transmit, Caps Lock PROGRAM F_DEFAULT Family Code Selection P.C. Record Suffix SS None 0 SS RETURN 1 SS TAB 2 SS SPACE 3 SS ENTER (Numeric Key Pad) 4 SS User defined character (1 character) SS None MS 1-15 characters Preamble Parameter Selection Option Code 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input. Scan “FIN” to terminate this selection.
Keyboard Interface Control User Instructions IDM corded series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions. Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, and then the Hand-held scanner will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state.
Keyboard Interface Control User Instructions IDM corded 2.5.4 Emulation Settings, Key Pad Emulation, Upper/Lower Case Settings PROGRAM F_DEFAULT Family Code Selection P.C. Parameter Selection Option Code Function Key Emulation SS Enable ASCII 00-31 code as keyboard function code output 0 SS Ctrl-Output 1 Refer to Appendix – Keyboard Function Code Table for details.
Serial Interface Control User Instructions IDM corded 2.6 Serial Interface Control 2.6.1 Record Suffix, Preamble, Postamble Settings PROGRAM F_DEFAULT Family Code Selection P.C. Parameter Selection Option Code STX/ ETX Control SS Disable STX/ETX transmission 0 SS Enable STX/ETX transmission 1 STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Serial Interface Control User Instructions IDM corded 2.6.2 Delay Settings PROGRAM F_DEFAULT Family Code Selection P.C. Parameter Selection Intermessage Delay SS None MS 1-99 (x5) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. Intercharacter Delay SS None MS 1-99 (x5) msec.
Serial Interface Control User Instructions IDM corded 2.6.3 Protocol, ACK/ NAK Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Serial Interface Control User Instructions IDM corded ACK Indication Disable: There’s neither LED nor beeping indication for this setting. Enable: There’s a specific LED and beeping indication for this setting. 2.6.4 Response Time-out, Baud Rate Settings PROGRAM F_DEFAULT Family Code Selection P.C.
Serial Interface Control User Instructions IDM corded 2.6.5 Data Frame Settings PROGRAM 52 F_DEFAULT Family Code Selection P.C.
Wand/ Laser Emulation Control (IDM1xx series) User Instructions IDM corded 2.7 Wand/ Laser Emulation Control (IDM1xx series) 2.7.1 Output Polarity, Signal State, Margin/ Module Time PROGRAM F_DEFAULT Family Code Selection P.C. Parameter Selection Option Code Output Polarity SS High level (5Vdc) on Bar (low level on Space) 0 SS Low level (0Vdc) on Bar (high level on Space) 1 Determine the output voltage level for both bar and space.
Operation Control (IDM1xx series) User Instructions IDM corded 2.8 Operation Control (IDM1xx series) 2.8.1 Operation Mode Setting PROGRAM F_DEFAULT Family Code Selection P.C.
User Instructions Operation Control (IDM1xx series) IDM corded Flash Mode (Pulse Driven Reading) The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a barcode, the scanner forces on the light source automatically and scans the barcode. Flash Duty Cycle adjustment can change the frequency of the blinking.
Operation Control (IDM1xx series) User Instructions IDM corded 2.8.2 Presentation Control, Scan Rate, Flash Duty PROGRAM F_DEFAULT Family Code Selection P.C.
Operation Control (IDM1xx series) User Instructions IDM corded 2.8.3 1D Barcode Reading Direction PROGRAM F_DEFAULT Family Code Selection P.C.
Operation Control (IDM2xx series) User Instructions IDM corded 2.9 Operation Control (IDM2xx series) 2.9.1 Operation, Presentation and Illumination Control PROGRAM F_DEFAULT Family Code Selection P.C.
Operation Control (IDM2xx series) User Instructions IDM corded 2.9.2 Aiming Control, Delay Aiming, Decode Aiming Control PROGRAM F_DEFAULT Family Code Selection P.C. Aiming Control SS Regular Aiming 0 SS Intelligent Aiming 1 SS Delay Aiming Control 2 Delay Aiming Time-out SS 200 ms 0 Control SS 400 ms 1 SS 800 ms 2 SS 1 sec 3 SS 1.5 secs. 4 SS 2 secs. 5 SS 3 secs. 6 SS 4 secs.
Operation Control (IDM2xx series) User Instructions IDM corded 2.9.3 Center Alignment, Unique Barcode Reporting PROGRAM F_DEFAULT Family Code Selection P.C.
Operation Control (IDM2xx series) User Instructions IDM corded 2.9.4 Batch Reading PROGRAM F_DEFAULT Family Code Selection P.C. Parameter Selection Batch reading SS None SS Batch reading rule input (01-16 rules) Option Code [FIN] [Rules] [FIN] Batch Reading When this function is enabled, you can scan multiple barcodes one by one continuously upon one trigger event. The scanner reports a good read beep and indication only if all bar codes set by the “Batch Reading Rule” are read.
Operation Control (IDM2xx series) User Instructions IDM corded [Code length] Length: 4 byte Specify what length of data output will be acceptable for this symbology. When you calculate the length, you must consider the whole data string which includes the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID or AIM ID. Scan the four digit data length from the Option Code. 40 is entered as 0040; 9999 is a universal number, indicating all lengths.
Operation Control (IDM2xx series) User Instructions IDM corded To program the previous example using specific lengths, you would have to count the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID Or AIM ID if you had defined as part of the length. If you enable the Suffix Symbol ID of symbology, you would add one character to the previous example’s length.
Operation Control (all IDM series) User Instructions IDM corded 2.10 Operation Control (all IDM series) 2.10.1 Buzzer, Indicator, Vibrator Control PROGRAM F_DEFAULT Family Code Selection P.C.
Operation Control (all IDM series) User Instructions IDM corded 2.10.2 Dollar Sign, Redundancy, 1D Code Inverse Reading PROGRAM F_DEFAULT Family Code Selection P.C.
Operation Control (all IDM series) User Instructions IDM corded 2.10.3 Reread Delay, Good Read Delay Control PROGRAM F_DEFAULT Family Code Selection P.C. Reread Delay SS Disable 0 (Double Scan Verification) SS Immediate time out 1 SS Short time out 2 SS Medium time out 3 SS Long time out 4 SS Force verification 5 SS None 0 SS 200 msec. 1 SS 500 msec. 2 SS 1 sec. 3 SS 1.5 sec. 4 SS 2 sec. 5 SS 3 sec.
Operation Control (all IDM series) User Instructions IDM corded 2.10.4 Light Source On Time, Hands Free Time-out PROGRAM F_DEFAULT Family Code Selection P.C. Light Source On Time SS Short 0 SS Medium 1 SS Long 2 SS Extremely long 3 SS Short 0 SS Medium 1 SS Long 2 SS Extremely long 3 SS Disable 4 SS Short 0 SS Medium 1 SS Long 2 SS Extremely long 3 SS Extremely short 4 Time Delay to Low Power SS 1 sec. 0 Mode SS 3 sec. 1 SS 5 sec.
Operation Control (all IDM series) User Instructions IDM corded 2.10.5 Presentation Auto-Sense , Sensitivity PROGRAM F_DEFAULT Family Code Selection P.C.
Condensed Data Wizard User Instructions IDM corded 2.11 Condensed Data Wizard DataWizard is a data editing system provided specially for the IDM hand-held scanners. Through DataWizard, you can process the scanned data prior the transmission in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help you to arrange the transmission of scanned data to any specific format without software modification.
Condensed Data Wizard User Instructions IDM corded 2.11.2 Data Formatter Settings The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired barcode symbologies for formatter control and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position. PROGRAM F_DEFAULT Family Code Selection P.C.
Condensed Data Wizard User Instructions IDM corded 2.11.3 Data Verifier Settings The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter. All data must conform to the Identified Barcode Symbologies, Identified Data Length, and one to three Identified Characters in the checking position.
Condensed Data Wizard User Instructions IDM corded 2.11.4 Data Replacer Settings The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired barcode symbologies for replacer control, and provides Multiple Position Replacement in the identified position. All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position.
Condensed Data Wizard User Instructions IDM corded 2.11.5 Data Organizer Settings The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired barcode symbologies for organizer control and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data including or excluding the data of identification position.
Condensed Data Wizard User Instructions IDM corded 2.11.6 Select a Barcode Symbology You can select one or all types of barcode symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the Hand-held scanner will arrange all incoming data to meet your pre-defined format. If you want to select only one type of barcode, please select one of the option codes listed below.
Condensed Data Wizard User Instructions IDM corded 2.11.7 Position Calculation Data Formatter If there is a 5-character input data string, refer to the following table to calculate the actual position for insertion: X X 00 01 X 02 X 03 X 04 05 Data Verifier, Data Replacer, Data Organizer If there is an 11-character data string, please refer to the following table to calculate the actual position for identification. X X X X X X X X X X X 00 01 02 03 04 05 06 07 08 09 10 2.11.
Condensed Data Wizard User Instructions IDM corded Data Formatter Scan “Formatter Control” and set the barcode symbology to “48”. Scan “1st Insertion” and set the identified position to “06”, then inserted characters to “09” (Hex Code of TAB), “53” (Hex Code of S), “4E” (Hex Code of N). Scan “2nd Insertion” and set the identified position to “12”, then inserted character to “09”. At the end, you must scan “FIN” (Finish) code to terminate this selection.
Symbology ID Table (1D Codes) User Instructions IDM corded 3 Appendix 3.1 Symbology ID Table (1D Codes) Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character; c = Code Character; m = Modifier Character Code Family UPC Code 128 Codabar Code 25 IATA Code 16K UCC Coupon Primary Format SICK ID AIM ID Hex Value Char. Code Char. Modified Char. UPC-A 2 0 A UPC-A with 2 supple. 32 1 UPC-A with 5 supple. 42 2 E UPC-E 3 0 E UPC-E with 2 supple.
Symbology ID table (2D and Post codes) User Instructions IDM corded 3.2 Symbology ID table (2D and Post codes) Code Family 3.3 Primary Format SICK ID AIM ID Hex Value Char. Code Char. Modified Char.
ASCII Input Shortcut (Reference Table) User Instructions IDM corded The last character in the Ctrl output column varies for different countries. Country (refer to Keyboard Layout) & Character 3.
Host Interface Quick Set User Instructions IDM corded 3.
Operation Mode Quick Set (IDM1xx series) User Instructions IDM corded 3.
Operation Mode Quick Set (IDM2xx series) User Instructions IDM corded 3.
Option Codes User Instructions IDM corded 3.
System Commands User Instructions IDM corded 3.9 System Commands PROGRAM (Enter Programming Mode) System Information List (SYSLIST) Safe User Default FIN (Finish) IDM Set Up Link User Default END (Exit Programming Mode) Master Default Factory Default Factory Default: After scanning “Factory Default” command, all parameters will be returned to factory default value.
User Instructions System Commands IDM corded 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice 85
8015906/2013-07-02 ∙ MT_8M/BU81 ∙ A4 4c int40 Australia Phone +61 3 9457 0600 1800 334 802 – tollfree E-Mail sales@sick.com.au Belgium/Luxembourg Phone +32 (0)2 466 55 66 E-Mail info@sick.be Brasil Phone +55 11 3215-4900 E-Mail sac@sick.com.br Canada Phone +1 905 771 14 44 E-Mail information@sick.com Ceská Republika Phone +420 2 57 91 18 50 E-Mail sick@sick.cz China Phone +86 4000 121 000 E-Mail info.china@sick.net.cn Phone +852-2153 6300 E-Mail ghk@sick.com.