System information

Reference Manual
I
DM
Bluetooth
Configure Your IDM BT
8014563/WE95/2012-07-25
© SICK AG · Germany · All rights reserved · Subject to change without notice
37
S
SS
S
PROGRAM
Symbology Reading Control
UPC/EAN Security Level Setting
Family Code Selection P.C Parameter Selection Option Code
UPC/EAN Security Level
SS
SS
SS
Level 0
Level 1
Level 2
Only available for UPC-A & EAN-13
0
1
2
EAN Supplement Control
SS
SS
SS
SS
SS
SS
SS
SS
Disable all specific prefix supplement digital output
Enable all specific prefix supplement digital output
Enable 491 Supplement Digit Output
Enable 978/979 Supplement Digit Output
Enable 977 Supplement Digit Output
Enable 378/379 Supplement Digit Output
Enable 414/419 Supplement Digit Output
Enable 434/439 Supplement Digit Output
0
1
2
3
4
5
6
7
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this
security level may significantly impair the decoding ability of the scanner.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may
increase the misread.