PROGRAMMING MANUAL IDM1xx Bluetooth Hand-held Scanners Hand-held Line
Revision History S Rev. No. Released Date Rev. A Jan.10, 2010 First Release Rev. A1 Mar.23, 2010 Modify UPC-E/EAN-8 expansion and UPC-A standardization. Add “Presentation Sensitivity”. Add “Extremely short” option to Good Read Duration. Jun.30, 2010 Add “UPC/EAN Security Level”. Baud Rate – Add 57.6K BPS and 115.2K BPS. Add “Immediate” parameter for "Time Delay to Low Power Trigger" and change the default value from 5 sections to immediate. Hands Free Time out – Add “Disable”. Rev.
Revision History S Rev. No. Released Date Rev. A6 Mar 04, 2011 Baud Rate – Revise 57.6K BPS and 115.2K BPS option code from 6.7. to 8.9. Rev. A7 Mar 07, 2011 Add ”Code 39 Security Level” Add “NAK Retry Count” Add “ACK/NAK Transmission Indication” Description Introduction of IDM160 Bluetooth Rev. A8 Jun 27, 2011 UCC/EAN-128 was renamed GS1-128. Add new parameter selections to “ACK/NAK Transmission Indication”. Add new parameter selections to “Serial Response Time-out”.
S Warranty The currently released status of SICK General Terms of Delivery Factory Automation and Logistics Automation shall apply Regulatory FCC, CE, CNS, LP, MIC LED Eye Safety IEC62471-1 LED Class 1 RohS All Bluetooth IDM devices are conform to RohS standards Reference Manual IDM Bluetooth Print out this manual If you want to print out this manual please ensure that the original size is remained and the print out is of good quality.
S Table of Contents Getting Started Getting Familiar with Your IDM BT Preparation before Using Decide Your Radio Link Mode Using IDM BT in PAIR Mode Using IDM BT in PICO Mode Using IDM BT in HID Mode Using IDM BT in SPP Mode Out-of-range Scanning/Presentation Scanning/Paging Function Batch Scanning (Inventory Mode) 5 7 9 10 11 13 14 16 17 Reference Manual IDM Bluetooth Configure Your IDM Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Control Keyboard Inter
Getting Started S Getting Familiar with Your IDM BT Thank you for choosing SICK IDM Bluetooth Scanners.
Getting Started S IDM140BT Charging Cradle IDM160-BT Charging Cradle Power Indicator Host Interface Port Reserved DC Power Jack Reference Manual IDM Bluetooth USB Bus Power Switch 8014563/WE95/2012-07-25 © SICK AG · Germany · All rights reserved · Subject to change without notice 7
Getting Started S Preparation before Using Install the Battery Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity. Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end cap. The scanner will give 4 beeps when the battery pack is installed properly if the battery pack still has power. Secure the end cap with the screw provided.
Getting Started Reference Manual IDM Bluetooth S Charge the Battery !! Please always ensure that you are using a battery with enough capacity. Otherwise it might happen that the scanner loses its radio connection !! Take care that the unit is placed properly inside the respective base or charging station. When unit is not placed properly, the charging is not guaranteed.
Getting Started S General Procedure Plug the AC power plug into the appropriate AC wall socket. Plug the DC power cord of the power supply unit into the DC power jack of the cradle. The cradle will issue the power on beeps. The center (upper) indicator of smart cradle will give one blue blink. The power indicator of charging cradle will turn steady blue. Place the scanner on the cradle. The status indicator of scanner will turn steady red if the battery is not fully charged.
Getting Started S Communication Cables Both the IDM140BT and the IDM160BT offer PS/2, USB and RS232 interface. USB The cable inlet of both IDM140BT and IDM160BT base station is on the bottom side.
Getting Started S Decide Your Radio Link Mode The IDM Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to one connection) or PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled IT assets.
Getting Started S Using IDM BT in PAIR Mode Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details. Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Please note that the scanner has been pre-paired already, if the scanner is shipped together with the smart cradle.
Getting Started S Using IDM BT in PICO Mode Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Reference Manual IDM Bluetooth Ensure the side (IDM140BT cradle) or lower indicator (IDM160BT cradle) of the smart cradle give alternative red and green blinks (in “Uninstall” state).
Getting Started S Clone Function For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration” command.
Getting Started S Using IDM BT in HID Mode Ensure the battery is fully charged. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “HID Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds.
Getting Started S Using IDM BT in SPP Mode Establish SPP Master Connection Ensure the battery is fully charged. Please go to the folder of “Hardware” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes. Ensure a virtual COM port is available in your remote host for connecting the scanner.
Getting Started S Establish SPP Slave Connection Ensure the battery is fully charged and a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of “Client Applications” located in Bluetooth Advanced Setting. Click the “Add COM Port” to add one more Bluetooth COM port. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state).
Getting Started S Out-of-range Scanning When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection with the remote host device. If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of working range.
Getting Started S Batch Scanning (Inventory Mode) Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000 EAN-13 labels. It is an ideal cost-saving solution for inventory applications. Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning.
Getting Started S Auto Delete Stored Data after Transmission Keep Stored Data after Transmission ◆ If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the ‘’Delete Last Scanned Data’’ command, the last stored data can be deleted.
Configure Your IDM BT S Bar Code Programming Manual The IDM BT bar code commands are specially designed Proprietary bar code labels which allow you to set the IDM BT internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Reference Manual IDM Bluetooth Each programmable family and bar code command label is listed on the same page with major system commands.
Configure Your IDM BT S Programming Procedures Reference Manual IDM Bluetooth As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the IDM’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options.
Configure Your IDM BT S Program & End System List, Group & Master Default Scan “PROGRAM” Scan “SYSLIST” IDM will enter programming mode, and inhibit all non-programming functions. revision number to host via selected host interface, IDM will list the product information and then issue the completion beeping.
Configure Your IDM BT S Single scan selection Scan “PROGRAM” Multiple scans selection Enter programming mode. Select one of desired Scan One of Family Codes programming families. Select one option code of Scan One of Option Codes Scan “PROGRAM” desired parameter. Enter programming mode. Select one of desired Scan One of Family Codes programming families. 1. Select one or several Scan One or Several Option Codes option codes to select desired parameters. 2.
Configure Your IDM BT S Cycling scan selection Dual level selection Scan “PROGRAM” Scan “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes Scan One of Family Codes programming families. Cycling select one or Scan One of Option Codes several option codes of desired parameters as Reference Manual IDM Bluetooth (2nd) Scan One or Several Option Codes Scan “FIN” 8014563/WE95/2012-07-25 1. Select one or several parameters. 2.
Configure Your IDM BT S Host Interface Selection Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ User Defined Symbol ID ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ Symbology ID Transmission ♦ Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ Readable Bar Code Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ Code 39/Code 32 Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ Code 39 Setting ♦ Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ EAN Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ UPC/EAN Security Level Setting ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ UCC Coupon Extended Code Setting ♦ PROGRAM Family Code Selection P.C UCC Coupon Extended Code SS SS Parameter Selection Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code Option Code 0 1 Reference Manual IDM Bluetooth UCC Coupon Extended Code When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99”, and GS1-128 Coupon Codes.
Configure Your IDM BT S Symbology Reading Control ♦ IATA & Interleaved 2 of 5 Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ Code 25 Family Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Symbology Reading Control ♦ Code 11 & Code 93 Setting ♦ PROGRAM Family Code Selection P.C Parameter Selection Code 11 Setting SS SS SS SS SS SS SS Disable Code 11 Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission Code 11 Min.
Configure Your IDM BT S Symbology Reading Control ♦ MSI/Plessey Setting ♦ PROGRAM Family Code Selection P.C Parameter Selection MSI/Plessey Setting SS SS SS SS SS SS SS Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission MSI/Plessey Min.
Configure Your IDM BT S Symbology Reading Control ♦ Code 128 & UCC/EAN 128 Setting ♦ PROGRAM Family Code Selection P.C Parameter Selection Code 128/EAN-128 Setting SS SS SS SS SS SS Disable Code 128 and GS1-128 Enable Code 128 and GS1-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On Code 128/EAN-128 Min.
Configure Your IDM BT S Symbology Reading Control ♦ UK/Plessey Setting ♦ PROGRAM Family Code Selection P.C Parameter Selection UK/Plessey Setting SS SS SS SS SS SS SS SS Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min.
Configure Your IDM BT S Symbology Reading Control ♦ Telepen Setting ♦ PROGRAM Family Code Selection P.C Parameter Selection Telepen Setting SS SS SS SS SS SS Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min.
Configure Your IDM BT S Symbology Reading Control ♦ GS1 DataBar Setting ♦ PROGRAM Family Code Selection P.C Parameter Selection GS1 DataBar Setting SS SS SS SS SS SS Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 DataBar Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 FIN (2 digits) Only available for Expanded GS1 Databar.
Configure Your IDM BT S Symbology Reading Control ♦ Linear-stacked & Korea Post Code Setting ♦ Reference Manual IDM Bluetooth PROGRAM Please note that stacked code only can be identified with IDMxxx PDF versions Family Code Selection P.
Configure Your IDM BT S Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦ PROGRAM Family Code Selection P.C Parameter Selection Record Suffix SS SS SS SS SS SS None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) Preamble SS MS None 1-15 characters Option Code 0 1 2 3 4 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your IDM BT S Keyboard Interface Control ♦ Delay Setting ♦ PROGRAM Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then IDM BT will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then IDM BT will terminate this selection automatically.
Configure Your IDM BT S Keyboard Interface Control ♦ Emulation Setting & Upper/Lower Case Setting ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Serial Interface Control ♦ Record Suffix, Preamble ,Postamble Setting ♦ PROGRAM Family Code Selection P.C STX/ETX Control SS SS Parameter Selection Option Code Disable STX/ETX transmission Enable STX/ETX transmission 0 1 Reference Manual IDM Bluetooth STX/ETX is two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Configure Your IDM BT S Serial Interface Control ♦ Delay Setting ♦ PROGRAM Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then IDM BT will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then IDM BT will terminate this selection automatically.
Configure Your IDM BT S Serial Interface Control ♦ Protocol, Baud Rate, Data Frame, ACK/NAK Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Serial Interface Control ♦Time Out Setting ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Wand/Laser Emulation Control ♦ Output Polarity, Signal State, Margin/Module Time, etc. ♦ PROGRAM Family Code Selection P.C Output Polarity SS SS Parameter Selection Option Code High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) 0 1 Determine the output voltage level for both bar and space.
Configure Your IDM BT S Operation Control ♦ Operation Mode ♦ PROGRAM Family Code Selection P.C Operation Mode SS SS Parameter Selection Trigger mode Presentation mode Option Code 1 2 Reference Manual IDM Bluetooth Trigger Mode (Low Power Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code.
Configure Your IDM BT S Operation Control ♦ Buzzer, Indicator, Vibrator, Inverse Reading ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Operation Control ♦ Dollar Sign Control, Redundancy, Scan Rate Control ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.C Parameter Selection Option Code Dollar Sign Control SS SS SS SS SS Dollar sign output as “ $ “ Dollar sign output as “¥“ Dollar sign output as “ € “ Dollar sign output as “ £ “ Dollar sign output as “ ¢ “ 0 1 2 3 4 Redundancy SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading.
Configure Your IDM BT S Operation Control ♦ Delay Setting ♦ PROGRAM Family Code Selection P.C Reread Delay SS SS SS SS SS SS Disable Immediate time out Short time out Medium time out Long time out Force verification 0 1 2 3 4 5 SS SS SS SS SS SS SS None 200 msec. 500 msec. 1 sec. 1.5 sec. 2 sec. 3 sec.
Configure Your IDM BT Reference Manual IDM Bluetooth S Operation Control ♦ Time-out Setting, Good Read Duration ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Operation Control ♦ Presentation Scanning Setting, Laser Aiming Control ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Operation Control ♦ Out-of-range Scanning, Sleep Time-out Control ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Operation Control ♦ Batch Scanning Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Operation Control ♦ Batch Scanning Data Transmission Setting ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Operation Control ♦ Bluetooth Device Name & Security Setting♦ ♦ Reference Manual IDM Bluetooth PROGRAM Family Code Selection P.
Configure Your IDM BT S Operation Control ♦ Bluetooth Other Settings ♦ PROGRAM Family Code Selection P.C Parameter Selection Option Code HID Link Quality Setting SS SS Disable Enable 0 1 Bluetooth Power Saving Mode SS SS Disable Enable 0 1 Reference Manual IDM Bluetooth The HID Link Quality Setting while using the HID radio link mode, some errors may occur during the data transmission when the radio link is disconnected.
Configure Your IDM BT S Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM Family Code Selection P.C Preamble SS MS Parameter Selection None 1-15 characters Option Code FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your IDM BT S Condensed DataWizard ♦ Data Formatter Setting ♦ PROGRAM Family Code Selection P.C Formatter Control SS MS MS 1st Insertion SS DS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) [1-3 characters], [FIN] 2-digits identified position; max.
Configure Your IDM BT S Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM Family Code Selection P.C Verifier Control SS MS MS SS MS Identified Data Length Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) Determine the identified data length for verification.
Configure Your IDM BT S Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S Condensed DataWizard ♦ Data Organizer Setting ♦ PROGRAM Family Code Selection P.
Configure Your IDM BT S [Data Verifier, Data Replacer, Data Organizer] Select a Bar Code Symbology Reference Manual IDM Bluetooth You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the IDM BT will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Configure Your IDM BT S Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Replacer Control” and set bar code symbology to “48”. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5). Reference Manual IDM Bluetooth Scan “Identified Data Length” and set the length to “16”. Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A).
Appendix S Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character The listed user defined characters are default values. User def. ID Code Family Primary Format AIM ID Code Code Modified Character Character Character UPC-A UPC-A with 2 supple. A UPC-A with 5 supple. UPC E UPC-E UPC-E with 2 supple. E Reference Manual UPC-E with 5 supple. IDM Bluetooth User def.
Appendix Reference Manual IDM Bluetooth S Keyboard Function Code Table No. ANSI ASCII 00 NUL 00H 01 SOH 02 Key Function No.
Appendix S ASCII Input Shortcut To configure the user definable parameters of IDM BT via programming menu, IDM BT will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p Example: 1 SOH DC1 ! 1 A Q a q If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference.
Appendix S Link Mode Quick Set Uninstall SPP Slave Mode PAIR Mode HID Mode SPP Master Mode Reference Manual IDM Bluetooth PICO Mode Operation Mode Quick Set Trigger Mode 8014563/WE95/2012-07-25 Presentation Mode © SICK AG · Germany · All rights reserved · Subject to change without notice 78
Appendix S Host Interface Quick Set (Work with Smart Cradle only) RS232 Serial PS/2 (DOS/V) KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode Reference Manual IDM Bluetooth USB HID Turbo Mode USB Com Port Emulation (additional software driver needed, available on sick.
Appendix S Option Codes 0 8 4 1 C 9 5 Reference Manual IDM Bluetooth 2 D A 6 3 E B 7 FIN (Finish) 8014563/WE95/2012-07-25 F END (Exit) © SICK AG · Germany · All rights reserved · Subject to change without notice 80
Appendix S System Commands PROGRAM (Enter Programming Mode) Save Configuration Sleep FIN (Finish) Clone Paging Reference Manual IDM Bluetooth END (Exit Programming Mode) Factory Default IDM Set Up Link (connection procedure see next page) System Information List (SYSLIST) Master Default Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the scanner will revert to uninstall state).
Appendix S How to connect IDM BT Scanner with configuration software IDM Set Up Tool The IDM Set Up Tool is a windows based configuration software for IDM scanners. The following steps describe how to configure an IDM Bluetooth scanner via this software tool. You can download the IDM Set up software for free on www.sick.com. 1. Make sure, that the Scanner is paired with the base station (pair mode). 2. The interface has to be set to RS232 or USB COM.
Appendix S Indications Link Indicator Reference Manual IDM Bluetooth Status Indicator Descriptions Radio connected Link Indicator 1 blue blink per 2.5 sec. Off Radio disconnected 3 blue blinks per 2 sec. Off During connection Quick blue blinks Short clicks Radio connection built 1 blue blink per 2.5 sec. 4 beeps in ascending tone Radio connection lost 3 blue blinks per 2 sec.
Appendix S Center (Power) Indicator Side Indicators Upper (Power) Indicator Lower indicator IDM BT Charging Cradle Indication Descriptions Power on Power Steady blue Beeper Off IDM BT Smart Cradle Indications Power on Indicators Center/Upper Side/Lower 1 blue blink Off Power on beeps Smart Cradle Upgrade State Off Steady red Short clicks Uninstall state Off Alternative red-green blinks Off Steady blue Steady Green Off Radio Disconnected Off Steady red Off Radio Connected Off Off Ra
8014563/WE95/2012-07-25 ∙ MT_8M/BU81 4c int38 Australia Phone +61 3 9457 0600 1800 334 802 – tollfree E-Mail sales@sick.com.au Belgium/Luxembourg Phone +32 (0)2 466 55 66 E-Mail info@sick.be Brasil Phone +55 11 3215-4900 E-Mail sac@sick.com.br Canada Phone +1(952) 941-6780 +1 (800) 325-7425 – tollfree E-Mail info@sickusa.com Ceská Republika Phone +420 2 57 91 18 50 E-Mail sick@sick.cz China Phone +852-2763 6966 E-Mail ghk@sick.com.hk Danmark Phone +45 45 82 64 00 E-Mail sick@sick.