Programming Manual

i480e&i480e-MD2 Programming Manual
18 /
139
i480e&i480e-MD2 Programming Manual
18 / 139
comma, the last parameter need not comma-tailed’
4
Generic AT Command Definition
This chapter introduces the generic AT commands’ definition, including a brief
description of commands’ syntax, responses and examples. All commands listed in
this chapter are profile-independent.
4.1GVER
The GVER command is used to get the version of the controller unit firmware.
Command
AT+B GVER
Response
AT-B GVER [ver]
Parameters
N/A
Note
N/A
4.2GLBD
The GLBD command is used to get the local Bluetooth device address.
Command
AT+B GLBD
Response
Succeed: AT-B GLBD 0,[bd]
Failed: AT-B GLBD 1,0
Parameters
bd
Local Bluetooth device address.
Note
bd is comprised of 12 bytes hexadecimal characters.
4.3GLDN
The GLDN command is used to get the local device name.
Command
AT+B GLDN
Barrot Confidential