Operator's Manual
barrett.net
19
TROUBLESHOOTING
MALFUNCTION CAUSE
CORRECTIVE
ACTION
FAILURE TO
EXTRACT
Broken or worn
extractor
Replace extractor
Broken or worn
extractor spring
Replace extractor
spring
Extractor not moving
freely
Clean extractor,
extractor spring, and
recess
Dirty ammunition or
chamber
Clean chamber and
insure ammunition
is clean
Broken case rim Clear chamber
FAILURE TO
EJECT
Broken or worn ejector Replace ejector
Broken or worn ejector
spring
Replace ejector
spring
Ejector not moving
freely
Clean ejector, ejector
spring, and recess