Specifications

The SC825 chassis includes a set of inner rails in two sections: inner rails and inner rail extensions.
Inner Rack Rails - The inner rails are pre-attached and do not interfere with normal use of the chassis if you decide not to use a server
rack. Attach the inner rail extension to stabilize the chassis within the rack.
Place the inner rack extensions on the side of the chassis, aligning the hooks of the chassis with the
rail extension holes. Verify the extension faces "outward" like the pre-attached inner rail.
Slide the extension toward the front of the chassis, and s ecure the chassis with 2 screws as shown
below.
Outer Rack Rails - Outer rails attach to the server rack and hold the server in place. The outer rails for the
SC836 chassis extend between 30 inches and 33 inches.
Assemble the outer rack rails using the diagram shown below:
Assemble Outer Rack Rails
Attach the outer rack rails and install the chassis into the rack as illustrated in the following diagram:
Install Chassis into the Rack