Installation Guide

Chapter 3 Management Centre Setup and Operations
BarMate Installation Guide
53
data point around the SAM is collected. This process is also
repeated for the location of each SRD.
If there is no response after collecting a data point (an
inactive data point textbox) or if a message, “Timeout
Occurred,” displays, simply re-enter the coordinates. In
some cases, the installer with the SRD may also need to
adjust their position so that the SAM is able to capture the
coordinates.
After completing the circumference, calculate and save the
parameters. This saves and updates the database with the
SAM calibration.
Reconfiguring the SRD for operation
After the SAM is calibrated, the SRD’s parameters must be
reset back to their original values.
To reconfigure the SRD for operation
1 Click the Settings tab, and then select SRD service
request response timeout.
2 Change the SRD service request response timeout
value to 60.
3 Click the Message tab, and then select the appropriate
SRD.
4 In the Test Commands group, select SRD RF Off.
5 Cycle the SRD’s power.
SRD re-registers with the Management Control Centre.
The SRD is now set to the proper RF to operate in the
BarMate system.