Shutter Function
This parameter control normal shutter and strobing features.
Shutter
The Shutter parameter determines sets the strobing rate.
Dim
The Dim parameter provides full mechanical dimming capability from closed at a DMX value of 0
to fully open at a DMX value of 255.
Shutter Options
DMX
Value
Description
Normal Shutter
Functions
0-31 Opens and closes shutter flags in the optical path
Random Random
Strobe
32-63 Strobes beam using the shutter flags at random intervals
Synchronous Random
Strobe
64-95
Synchronizes random strobing for all Technospot fixtures using the
same DMX controller
Normal Shutter
Functions
96-255 Opens and closes shutter flags in the optical path
DMX
Value
Shutter Parameter Options
0-23 Close shutter
24-229 Set strobe rate from slowest to fastest
230-255 Open shutter