User manual

CHAPTER 3
The Menu System
Cyberlight
®
2.0 User Manual 23
Performing Self Tests (SELF)
The following self tests are available:
Parameter Self-Test Description
PAN Moves through the entire pan range
TILT Moves through the entire tilt range
SHUT Tests Shutter strobe movement
CYAN
Moves the specific pair of color flags selectedMAGN
YELW
COLR Static color wheel function
LT1 Rotating Gobo Wheel: wheel movement
LT1R Rotating Gobo Wheel: rotating gobo movement
LT2 Static Gobo Wheel movement
IRIS Tests Iris function
FX Tests Effects wheel motion
ZOOM Moves the Zoom lens through the range
FCUS Moves through the Focus range
FRST Tests Frost flags movement
To start a self test process:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the TEST menu. Press <Enter> to select.
3. Scroll to the SELF menu. Press <Enter> to select.
4. Scroll to the desired option (listed above).
5. Press <Enter> to start the test. The fixture will perform the selected self test.
6. Press <Menu> to exit the test.
Moving the Fixture to Setup Position (S/UP)
Caution: The setup position is used only by qualified service
personnel during maintenance.
To place the fixture in setup position before servicing:
1. Hold <MENU> until the display changes to AddR.
2. Using the up and down buttons, scroll to the TEST field and press <ENTER>.
3. Using the up and down buttons, scroll to the S/UP field and press <ENTER>. The display
will indicate SET NOW while the motors are electronically locked into place.
4. Perform the appropriate maintenance procedures.
5. Press <MENU> to reset and home the fixture.