Service manual
Connecting for local PC control on the remote connector
33
2
◆
Connecting for local PC control on the remote connector
To connect a PC to the
remote connector
To enable local communication between the S
TELLAR
and the PC, do the following:
1. Connect the Com port on the PC to the remote connector on the S
TELLAR
.
The remote connector is placed on the connector panel of the S
TELLAR
and is
labelled “RS-485”. It is a 9-pin male Sub-D connector which connects to the RS-
485 port of the PC using a 9-way cable. The cable may be unshielded.
The following table shows the connector and the pin allocation.
2. Configure the PC COM port in ROSA.
From the C
OPERNICUS
explorer, right-click on your COM port and select “Prop-
erties”. Select the “RCDS protocol” driver.
To convert from RS-232
to RS-485
If your PC is not equipped with an RS-485 I/O card you need an RS-232 to RS-485
9-pin sub-D converter. The order number is 806352.
Connect the RS-232 side of the adapter as close to the PC as possible, preferably con-
nected directly to the PC port. The RS-485 connector connects to the S
TELLAR
via a
9-way shielded cable. The converter does not require external power.
Connector drawing Pin number Description Use
pin 1 - Not connected
pin2 TxB Datatohost
pin 3 RxB Data from host
pin4 TxA Datatohost
pin 5 RxA Data from host
pin 6 - Not connected
pin 7 Ground Signal ground
pin 8 - Not connected
pin 9 - Not connected
1
9
98-022