Service manual

24
Connecting the output signals
2
Installation
mono is output on both connectors.
The digital AES/EBU audio output for audio channel 1 is connected to
the XLR connector marked AUDIO OUT 1 AES/EBU.
Auxiliary data output One unidirectional auxiliary data channel may be decoded from the incoming data
stream. The auxiliary data channel which was assigned to the video channel will be
decoded in the decoder. The auxiliary data is output on both the AUX RS-232 and the
AUX RS-422 connector.
RS-232 aux. pin
allocation
The following table shows the connector and the pin allocation for the RS-232 data
output.
RS-422 aux. pin
allocation
The following table shows the connector and the pin allocation for the RS-422 data
output.
Nx64kbit/sdata A synchronous N x 64 kbit/s data channel (N is one to six) may be decoded from the
incoming data stream. The data is output at the N x 64 kbit/s Out connector.
Connector Pin allocation Output signal
1: Not connected
2: RxD (output)
3: Not connected
4: DTR (input)
5: Ground
6: DSR (output)
7: Not connected
8: CTS (output)
9: Not connected
Transparent data channel
RS-232-E, at a bit rate of 600
to 38400 baud.
Connector type: 9-pin sub-D
female.
1
9
Connector Pin allocation Output signal
1: Shield
2: TxA (output)
3: Not connected
4: Ground
5: Not connected
6: Ground
7: TxB (output)
8: Not connected
9: Ground
Transparent data channel
RS-422, at a bit rate of 600 to
38400 baud.
Connector type: 9-pin sub-D
female.
1
9