Service manual
Auxiliary data output
A-19
A
◆
Data output
◆
Auxiliary data output
Auxiliarydataoutput Number of outputs 2
Connector type 9-pole sub-D female (DCE)
Type of output Uni-directional, asynchronous RS-
232-E and RS-422
Handshake
RS-232 CTS, RTS active, DTR, DSR pas-
sive
RS-422 None
Baud rates 600, 1200, 2400, 4800,
9600,19200, 38400
Data format 8N1, no parity
◆
Synchronous N x 64 kbit/s data output
Nx64kbit/sdata
output
Bit rates N x 64 kbit/s. N = 1, 2, 3, 4, 5 or 6.
Electrical Interface Acc. to RS-422
Number of outputs 1
Connector 9 pole Sub-D female
Output clock rate Locked to data input on encoder
Operating mode Only DCE
Output impedance < 20 Ω