ROSA messages
5
Service and maintenance
7 Communication
port error
Communica
tion error
On Information Disable Check the terminal settings.
2 Contact closure
occurred
Close On Information Disable One of the contact closure contacts has
closed and thereby activated a macro.
Reload the ROSA windows to get the
actual settings from the decoder.
Open On Information Disable One of the contact closure contacts has
opened and thereby activated a macro.
Reload the ROSA windows to get the
actual settings from the decoder.
34 Device software
error
General
software
error
Off Information Disable A software error has occurred. When
persistent, contact your local BARCO
sales office for further assistance.
RTK related
SW error
Off Information Disable A software error has occurred. When
persistent, contact your local BARCO
sales office for further assistance.
36 Hardware failure Module
hardware
error
On Information A Replace the module in question.
Module
selftest error
On Information B The self-test has failed. Replace the
module in question.
37 Module
configuration
error
Misplaced
module
On Major B A module was missing at power-up or a
known module was misplaced.
Module is
removed
On Major B A module is missing. Replace the module
or make a new configuration.
Module is
unknown
On Major B The module is not known by the system
controller. The module stock number may
be lost or your system controller software
is too old to handle the module.
No module
handler
On Major A The stock number of the module is not
known to the system controller. Check the
stock number and slot position of the
module. Check if the firmware supports
the module.
Pig.
misplaced or
missing
On Major B The reference check of the piggy-back
module failed, indicating that the module
is either misplaced or missing.
40 MPEG PSI error PCR
accuracy
error
On Major A The PLL cannot lock to the PCR values
due to inaccuracy (e.g. excessive jitter,
frequency error, etc.). Set the Video
Synchronization mode to "Free Running".
Program not
in PAT
On Warning B The selected program is not found in the
PAT. Check the source and select the
correct program.
No. Information Name Enabled Severity Category Explanation/Remedy