Instruction manual
15. Troubleshooter RLM R5 Performer
15.2 Led 1, 2 and 3 light up Red continuously
Troubleshooter
Trouble Shooter RLM G5P
Led1-Led2 and Led3 light up Red
(continuously)
Led1-Led2 and Led3
light up Red
(continuously)
OK
NOK
Led3
Led2
Led1
Power down the projector
and
Replace the Lamp module
NOK
Replace the
cable
NOK
Replace the
MCU Board
OK
Check the
Cable between
J1 lamp Info Board and
J900 MCU Board
Check the
Cable plug J1 on
lamp Info Board
J1[1,3,4]=+5V
NOK
Check on
MCU Board
J900 [1,3,4]=+5V
Replace the
MCU Board
NOK
OK
Remove cable plug J505
on MCU Board
Check on
MCU Board
J505 [2,3]=+5V
Replace the
MCU Board
NOK
Replace the
Cable
NOK
Replace the
PMP Board
OK
Check the
Cable between
J505 MCU Board and
J595 PMP Board
OK
OK
Image 15-2
Troubleshooter Standby mode
96 R5976766 RLM G5 22/04/2004