Instruction manual
15. Troubleshooter RLM R5 Performer
15. TROUBLESHOOTER RLM R5 PERFORMER
15.1 Start-up without audible relay click
Troubleshooter
cn12[4]
Trouble Shooter RLM G5P
Start-up without audible relay click
No relay click
sound when
switching on
NOK
OK
Connect to another
Power Outlet
NOK
Replace the
Power Cord
OK
NOK
Replace the
Power Input Unit
Order No: R401044K*
*Contents R401044K
- Power outlet
- Power Switch
- cable to PFC
OK
cn5[2-4]
cn55[1]
cn55[4]
Replace the
PFC Board
Check the
PFC output
+15V cn55[4]
OK
NOK
Replace the
StandBy Power
Board
NOK
Check the
Power Outlet
Check the
Projector
Power Input
Check the
Power Input on
PFC (cn5)
Check the
PFC In/Output Voltages
cn55[1] 375V
cn55[4] +15V
StandBy Power
Board
PFC Power
Board
Image 15-1
Troublesho
oter start-up
R5976766 RLM G5 22/04/2004 95