User`s manual
Reference Carrier Input P
ULSAR
BG
Page 2
3.2 Installing The Reference Carrier Board
If needed, solder the three pins of the two supporting plates in the correct place. (see layout diagram)
•
Cable connections to be made.
Cable From To
Reference Input Cable REF IN connector
J2 on the optional board
Power Supply Cable 1
Remove from J21 on the main-
board.
Connect this end to J5 on the
optional board.
Power Supply Cable 2 (13-wire)
J1 on the optional board J21 on the mainboard
Reference Output Cable
N5 on the optional board J25 on the mainboard
Control Cable
N1, N2 & N3 on the optional
board
BR4 on the mainboard (remove
BR4 first)
•
Place the optional board over the tabs and twist them so the board will be fixed.
•
Use the delivered cable ties to tight the cables.
3.3 Closing The PULSAR
•
Put the bottom cover back onto the chassis.
•
Tighten the nine screws (Torx 10) while pressing the bottom cover down.
•
Turn the P
ULSAR upright.
•
Put the top cover onto the chassis.
•
Tighten the nine screws (Torx 10) while pressing the top cover down.
•
Replug the power cord.