User`s manual

P
ULSAR
BG IF Vision / IF Sond Loops
Page 1
1 DESCRIPTION
The IF vision signal as well as the IF sound 1 signal can be taken from the PULSAR. Another device
will use these IF signals (or one of them) and put the processed signal back to the P
ULSAR. Such a
device is e.g. a scrambler.
2 SPECIFICATIONS
- Connector............................................................................... F, 75 Ohm
- Input, Output levels
IF Vision Loop before SAW .......................................... +46 dBmV
IF Sound Loop (1)......................................................... +34 dBmV
3 INSTALLATION
Please read this chapter carefully before installing the option.
The installation procedure is only necessary when ordering this option sepa-
rately. When ordering a P
ULSAR with IF Vision / IF Sound Loops, the installa-
tion has already been carried out during production.
For location of the boards, connectors and jumpers use the internal layout diagram
Before changing anything in the P
ULSAR, remove the power cord to switch off
the power supply.
3.1 Opening The PULSAR
Unplug the power cord to turn off the P
ULSAR.
Unscrew the nine screws (Torx 10) holding the top cover.
Pull the top cover backwards and remove it.
Loosen the nine screws (Torx 10) holding the bottom cover.
Remove the bottom cover.
3.2 Installing The Coaxial Cables
Remove the 4 black bushing domes on the VIS IF and SND IF positions. See chapter 4 : Layout.
VISION IF LOOP
Bridges to set on the mainboard
Bridge Function Position
BR9
Enables / Disables IF Vision Loop before SAW remove
OPTION: IF VISION / IF SOUND LOOPS
ORDER NUMBER: C982516
WARNING
REMARK