User`s manual

P
ULSAR
Operation
Page 5-9
5.4.2 RF Output Level
The RF output level can be set between 50 and 60 dBmV in steps of 0.5 dB. The factory setting is 60
dBmV.
5.4.3 S/V Ratio
The S/V ratio can be changed between –8 and –20 dB. The factory setting is – 13 dB.
In case of two sound carriers: the S1/V and S2/V ratio are displayed. The S1/V ratio can be changed
between –11 and –23 dB and is default –13 dB. The level of S2/V is default –20 dB and changes propor-
tional to the S1/V value i.e. if S1/V is reduced with 2 dB, S2/V will also automatically be reduced with 2
dB. Cable network characteristics could influence these levels and result in a wrong sound2/sound1
ratio.That’s why it is also possible to adjust the S2/S1 ratio with –2dB/+3dB.
5.4.4 Calibration Slope
The slope of the RF output signal can be recalibrated. Recalibration is necessary in case a new filter
module has been installed or whenever calibration seems to be necessary.
5.4.5 Slope Control
This feature is very useful to align the PULSAR in the headend after combining all modulated signals to be
sent on the network. Use measurement equipment e.g. a spectrum analyser to check the slope of the
P
ULAR’s RF output after being combined with all the other channels. It is possible that the slope of the RF
spektrum is not flat anymore because of f.i. network characteristics. This can be compensated by tilting
up or down the slope of the P
ULSAR’s output.
Next to the control bar, the state of the slope is shown:
FLAT: No correction is done w.r.t. the calibrated slope
TILT UP: The slope is tilted up on the high frequency end.
TILT DOWN: The slope is tilted down on the high frequency end.
5.4.6 RF OUTPUT
The RF output can be switched on or off
In case of a PLL unlock error the RF output cannot be switched on.
5.4.7 Int. Sound Carrier
Use this submenu to switch on/off the internally generated sound carrier. In case of stereo sound the
internal sound carrier 1 will be displayed. The second internal sound carrier will be shown in the next
display.
5.4.8 Clamping-VAGC- Mod meter
These three important settings are shown on the same display because they are related to each other.
The
LEFT and RIGHT arrows are used to move through the different submenus. Press the UP and DOWN
arrow to enter into the edit mode of the different functions. The second line starts blinking.