User`s manual

P
ULSAR
BG Installation
Page 4-5
4.3.1 RS-485 Remote Control
The RS-485 Remote Control connector is a 9-pins SubD male connector. All important modulator
parameters such as RF level, modulation depth, audio deviation and all possible functional selections
can be remotely controlled from a PC with B
ARCOS ROSA software and/or the client-server
ROSA/COPERNICUS system. This makes it possible to use the PULSAR in applications such as digital to
analog nodes in super trunk systems and headends in rural or remote areas. Using the P
ULSAR with
other remote controllable equipment, such as
FSM 860, SAT 200, QUASAR, allows the operator to have
complete control over the headend.
Pin Function Pin Function
1 Not Connected 6 Not Connected
2 TxB 7 Floating
3 RxB 8 Not Connected
4 TxA 9 Not Connected
RS 485
1
9
5RxA
Pin 7 : floating or grounded, selectable with bridge BR2 on the mainboard.
4.3.2 Audio Input - Status & Control
4.3.2.1 Audio Inputs
The upper row of the screw terminal is used as input for the baseband audio signal, the configuration
of the terminal is:
PIN Function PIN Function
1 MAIN input left or mono (+) 7 AUX input left or mono (+)
2 MAIN input left or mono (-) 8 AUX input left or mono (-)
3 Ground 9 Ground
4 MAIN input right (+) 10 AUX input right (+)
5 MAIN input right (-) 11 AUX input right (-)
6 Ground 12 Ground
AUDIO INPUTS
STATUS & CONTROL
I
II
121