User`s manual

P
ULSAR
BG Separate IF Outputs
Page 5
5 ALIGNMENT
Start the alignment with executing FACTORY RECALL in the CONFIG menu.
SYSTEM
STATUS LOCK
CONFIG
FACTORY RECALL:
EXECUTE
After a factory recall the three output levels are put on +40 dBmV. It is possible to do some fine
tuning with the potentiometer P2 and P1 in case of a dual sound carrier system.
Connect a spectrum analyzer to the IFv Out connector on the rear panel. Check if the level is
+40 dBmV.
Connect a spectrum analyzer to the IFs1 Out connector on the rear panel. Check if the level is
+40 dBmV. When the level is not +40 dBmV it can be adjusted with potentiometer P2 until the level is
reached.
Connect a spectrum analyzer to the IFs2 Out connector on the rear panel. Check if the level is
+40 dBmV. When the level is not +40 dBmV it can be adjusted with potentiometer P1 until the level is
reached.