User Manual and Operating Guide
3. Commands
Request
Pos Size Name Description Content
0 1 get resolution
0xF0
get resolution (hex)
1 1 get resolution
0x01
get resolution (hex)
Response
Pos
Size
Name Description
Content
0 1 get resolution
0xF0
get resolution (hex)
1 1 get resolution
0x01
get resolution (hex)
BYTE 1 (hex)
BYTE 2 (hex)
BYTE 3 (hex)
2-5 4 resolution value
Resolutioncanbecalculatedfromthe
4bytes:
X-resolution = BYTE 1 * 256 + BY T E2
Y-resolution = BYTE 3 * 256 + BY T E4
BYTE 4 (hex)
3.44 get saturation, read
About this comma nd
This command gets the saturation value of the active source.
Request
Pos
Size
Name Description
Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 adj saturation
0x03
adj saturation (hex)
Response
Pos
Size
Name Description
Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 adj saturation
0x03
adj saturation (hex)
2 1 saturation value range 0->255
saturation value (hex)
3.45 get serial number, read
About this comma nd
This command gets the serial number of the pro jector.
Request
Pos
Size
Name Description
Content
0x2A
0x08
0-2 3 get serial num ber
0xA2
Response
Pos Size Name Description Content
0x2A
0x08
0-2 3 get serial num ber
0xA2
32 R5905746 COMMAND CATALOG 06/01/2014