User Manual and Operating Guide

3. Commands
Request
Pos Size Name Description Content
0 1 get PIP enable
0xA1
get PIP enable (hex)
1 1 get PIP enable
0x01
get PIP enable (hex)
Response
Pos
Size
Name Description
Content
0 1 get PIP enable
0xA1
get PIP enable (hex)
1 1 get PIP enable
0x01
get PIP enable (hex)
0x00
Off (hex)
2 1 PIP enable value
0x01
On (hex)
3.39 get PIP position, write
About this comma nd
This command gets the PIP position.
Request
Pos
Size
Name Description
Content
0 1 get PIP position
0xA1
get PIP position (hex)
1 1 get PIP position
0x04
get PIP position (hex)
Response
Pos
Size
Name Description
Content
0 1 get PIP position
0xA1
get PIP position (hex)
1 1 get PIP position
0x04
get PIP position (hex)
0x00
top left (hex)
0x01
top right (hex)
0x02
bottom left (hex)
2 1 PIP position value
0x03
bottom right (hex)
3.40 get PIP select, read
About this comma nd
This command gets the PIP select value.
Request
Pos
Size
Name Description
Content
0 1 get PIP select
0xA1
get PIP select (hex )
1 1 get PIP select
0x02
get PIP select (hex )
Response
Pos Size Name Description Content
0 1 get PIP select
0xA1
get PIP select (hex )
1 1 get PIP select
0x02
get PIP select (hex )
30 R5905746 COMMAND CATALOG 06/01/2014