User Manual and Operating Guide
3. Commands
Request
Pos Size Name Description Content
0x2A
0x06
0-2 3 get IP configuration info
0xA2
Response
Pos
Size
Name Description
Content
0x2A
0x06
0-2 3
get IP configuration info
0xA2
first octet (h ex)
second octet (hex)
third octet (hex)
3-6 4 IP address
fourth octet (hex)
first octet (h ex)
second octet (hex)
third octet (hex)
7-10 4 subnet mask
fourth octet (hex)
first octet (h ex)
second octet (hex)
third octet (hex)
11-14 4
default gateway
fourth octet (hex)
0x00
Off (hex)
15 1
DHCP
0x01
On (hex)
BYTE1 ( hex)
BYTE2 ( hex)
BYTE3 ( hex)
BYTE4 ( hex)
BYTE5 ( hex)
16-21 6 LAN FW version
BYTE6 ( hex)
first octet (h ex)
second octet (hex)
third octet (hex)
fourth octet (hex)
fifth octet (hex)
22-27 6
MAC addres s
sixth octet (hex)
3.29 get lamp max run time, read
About this comma nd
This command gets the maximum runtime of the lamp.
Request
Pos
Size
Name Description
Content
01lamp
0x76
lamp (hex)
1 1 get lam p max runtime
0x89
get lamp max r untime ( hex)
R5905746 COMMAND CATALOG 06/01/2014 25