Projector User Manual
2. PMP kit
2. PMP KIT
2.1 Introduction
Introduction
In case of failure of a PM P, it must be replaced by a (blank) new one. However, since most of the projector related data is stored
on this boa rd, this data will be lost while replacing the board. This includes not only key data such as Projector Device Typ e and
Projector Serial Number, but also the full set of factory se ttings of the projector which are indispensable to get a good quality image:
uniformity, colors, g ray levels, etc. Not having this factory settings will definitely result in a POOR QUALITY IMAGE.
To avoid loss of data, it isamustto m ake a backup of all the settings using the software tool Projector Support. This tool m akes
it possible to m ake a full backup, including P rojector Device Type, Projector Serial Number and Runtimes and full factory settings.
When restoring the (original!) backup on a (blank!) PMP, it will be fully configured in the w ay it was by the time of the backup.
In the situation where n o backup is available a nd the PMP is not working properly, try to conne
ct to the projector via Ethernet anyway
and use the Projector Su pport tool to make a backup. Mos t probably, this will be successful. If not, you will have to contact Barco.
The Projector S upport tool can be found on TDE on BarcoZone ( http://kuunet.barc o.com/bgs/ global/TDE2/ ):
search for Software, using string “Projector S upport”)
2.2 Kit description
Scope
Two different kits are available. The ta ble below points out wh
ich one to us e.
Kit number Projector type Projector article number
Galax y NH-12
R9040400
NH-12 R9010610
iD LH-12 R9010620
R7649672K
iCon NH-12
R9010600
Galaxy NW-12
R9040410
R7649676K
NW-12 R9010700
Kit content
The kit c ontains a blank PMP.
2.3 Kit installation (overview)
Overview of the kit installation
1. Use Projector Support tool and mak
e a backup of the se ttings of the PMP to be replac ed
2. Replace the faulty PMP by the new one of the kit
3. Restore the backup
4. Upgrade the projector to the de sired s oftware v ersion
R59770498 PMP KIT 28/02/2011